background image

5. 

Each bath can be programmed with the following options.  Use the “DOWN” and “UP” keys to 
select the desired setting and the “START” key to move to the next option. 

 
DISPLAY FUNCTION 

OPTIONS 

Ct   ** 

Tumble Time 

Two-digit amount of time in minutes. 

t     ** 

Water Temperature 

HH for hot, CH for warm, CC for cold 
and EE for no water. 

L  ** 

Water Level 

Lo for low, Hl for high. 

dF   * 

Type of Fill 

d for delayed fill, t for timed fill.

1

S  ** 

Spin Time 

Two-digit amount of time in minutes. 

IS  * 

Injection Source 

Single digit code indicating injector signal(s).

2

 

A delayed fill will pause the time count until the selected level is reached.  A timed fill will 

allow the time count to continue until the selected level is reached. 

2

 Codes for injections sources are defined at the end of the programming section. When the No 

Water bath is selected, the electronic controller prohibits injection signals.  The programmed 
injection source value is ignored. 

 
To exit the programming of a bath, press the “STOP” button once and use the “UP” and “DOWN” 
keys select another bath.  Press the “STOP” button again to select a different cycle to change.  To 
end programming, turn the key to “RUN” position  
 
 

Note:

  The Wash Cycle programming mode will automatically exit and return to 

the Idle mode if no buttons are pushed for one minute. 

 
 
 
 
WASH CYCLE PARAMETER RANGES 

 

The range of each cycle parameter is shown below: 

 

Cycle Time 

 

 

0 to 15 minutes for Prewash, Wash, Rinse1, 2, 3 and 4 
1 to 15 minutes for Final Rinse 
For the bathes that can, if the time is set to zero, then the bath 
will be eliminated from the cycle. 

Water Temperature 

 

HH – hot, CH – warm, CC – cold, EE – no water 

Water Level   

 

HI – high, LO – low 

Delay Fill 

 

 

The selections are “d” for delay the bath time until water level 
is reached or “t” to count down bath time during the fill. 

Spin Time 

 

 

0 to 10 minutes for Prewash, Wash, Rinse, 2, 3 and 4 
1 to 10 minutes for Final Spin 

Injection Source 

 

0 to 6 

 

Summary of Contents for HIGH SPEED 25LB WASHER

Page 1: ...r 5 Do not use volatile or flammable substances in or near this washer 6 Keep all panels in place They protect against shock and injury and add rigidity to the washer PREVENTIVE MAINTENANCE REQUIREMEN...

Page 2: ...grouted to a substantial concrete floor CARE MUST BE STRESSED WITH ALL FOUNDATION WORK TO INSURE A STABLE UNIT INSTALLATION ELIMINATING POSSIBILITIES OF EXCESSIVE VIBRATION All installations must be...

Page 3: ......

Page 4: ...separation distance of at least 3mm must be provided The connection should be sheathed in liquid tight flexible conduit or equivalent with conductors of the proper size and insulation TO MAKE ELECTRI...

Page 5: ...the external injection signals For the injection sources program codes 0 through 6 are as shown in the table below Dexter Recommended Connections Controller Programmed Signals Injection Terminal Bloc...

Page 6: ...ONTROL WATER INLET DRAIN VALVE 25LBS 4 CUBIC FT 11 3 kg 113 L 25 DIA X 14 1 8 DEEP 63 5cm X 36cm 208 240 VAC 60 HZ 1 OR 3 PHASE SOFT START REVERSING INVERTER DRIVE 2 HP MOTOR 50 RPM 410 RPM 60 G S 750...

Page 7: ...re used in the detergent compartment they must be added at the beginning of the wash cycle If the machine is set for pre wash washing products can be added to the round opening of the dispenser or put...

Page 8: ...am key to the Program position Display will show C O and the ADD BLEACH light will blink and will continue to blink during the programming mode 3 Press the DOWN or UP buttons to select which cycle to...

Page 9: ...prohibits injection signals The programmed injection source value is ignored To exit the programming of a bath press the STOP button once and use the UP and DOWN keys select another bath Press the ST...

Page 10: ...O d 2 Bleach Rinse 2 2 CH HI d 1 Rinse 3 2 CH HI d Rinse 4 Final Rinse 4 CH LO d 4 4 Sour Soft Cycle 2 Towels Pads Diapers Health Care Bath Bath Cycle Time min Water Temp Water Level Delay Fill Spin T...

Page 11: ...7 HH LO d 2 Bleach Rinse 3 2 CH HI d 1 Rinse 4 2 CH HI d Final Rinse 4 CH LO d 5 4 Sour Soft Cycle 4 Guest Laundry Hotel Motel or Health Care Bath Bath Cycle Time min Water Temp Water Level Delay Fil...

Page 12: ...ergent Rinse 2 2 HH HI d Rinse 3 7 HH LO d 2 Bleach Rinse 4 2 CH HI d 1 Final Rinse 2 CH LO d 5 Cycle 6 Colored Cotton Linen Food Beverage Bath Bath Cycle Time min Water Temp Water Level Delay Fill Sp...

Page 13: ...pid advance mode even if the key is turned to RUN and or removed Rapid advance cannot skip the final 1 minute tumble of the cycle and the door lock may remain activated for a couple minutes after the...

Page 14: ...ply 2 8641 242 000 Washer Inlet Hose 2 9565 003 001 Strainer Inlet Hose 4 INSTALLATION Available through Dexter Distributor 9242 417 003 3 76 mm Flex Drain Hose 10 ft length 3 meters Contact your dist...

Reviews: