Dexter Laundry 80LB CAPACITY COMPUTER CONTROL OPL WASHER T1200 Installation & Operation Manual Download Page 8

STARTING THE WASHER 
 

A.  Load the clothes into the cylinder and latch the door securely.  Be sure clothing does 
not get caught between the door gasket and tub front when closing the door.  Maximum 
load is 80 pounds clothes, dry weight. Do not load the washer with more than 80 lbs. 

 

B.  Select the appropriate cycle number (1 through 6) using for the load being washed. 
See the cycle descriptions in the programming section. Use the UP and DOWN keys to 
change the cycle number. 

 

C.  If not using a chemical injection system, add low-sudsing powdered detergent into the 
“detergent” compartment of the automatic dispenser on the top of the washer.  If desired 
add fabric softener to the “fabric softener” compartment.  Use the amount of fabric 
softener as recommended by the manufacturer. 
 
If liquid wash products are used in the “detergent” compartment, they must be added at  
the beginning of the wash cycle. 

 

If the machine is set for pre-wash, washing products can be added to the round opening of 
the dispenser or put in with the clothes when loading the cylinder before starting the 
machine. 

 

D.  Press START.  The display will go blank for a moment and then display the cycle 
time in minutes.  The clothes door will lock and remain locked until the end of the cycle.   

 
END OF CYCLE 
 
When the cycle is complete the time will display “0” until the door is opened and a 5-second tone 
will sound.  The door can now be opened.  Leave the clothes door open when the machine is not 
in use. 
 
SAFETY DOOR LOCK 
 
This machine is equipped with a Safety Door Lock that prevents opening the door for 2 to 3 
minutes if the power is interrupted.  This safety feature cannot be bypassed. 

Summary of Contents for 80LB CAPACITY COMPUTER CONTROL OPL WASHER T1200

Page 1: ...of this washer 5 Do not use volatile or flammable substances in or near this washer 6 Keep all panels in place They protect against shock and injury and add rigidity to the washer PREVENTIVE MAINTENAN...

Page 2: ...ct desired wash CYCLE with and buttons ADD BLEACH light comes on 5 If bleach is required add when 4 Press START button RINSE WASH PRE FLUSH WASH RINSE FINAL SPIN 1 Load clothes and latch door firmly I...

Page 3: ...XCESSIVE VIBRATION All installations must be made on sound concrete floors 8 inches 203 mm or thicker Anchor bolts or expansion anchors must be of a quality grade and a minimum of 3 4 inch 19 mm diame...

Page 4: ...CONCRETE PEDESTAL MOUNTING Figure 1 1 Figure 1 2 FLOOR OUTLINE Figure 1 3 MACHINE MOUNTING DETAIL...

Page 5: ...ided The machine should be connected to an individual branch circuit not shared by lighting or other equipment The connection should be sheathed in liquid tight flexible conduit or equivalent with con...

Page 6: ...connection of the external injection signals For the injection sources program codes 0 through 6 are as shown in the table below Dexter Recommended Connections Controller Programmed Signals Injection...

Page 7: ...AL EXTRACT MACHINE CONTROL WATER INLET DRAIN VALVE 80LBS 11 5 CUBIC FT 36 3 kg 326 l 30 DIA X 28 DEEP 76cm X 71cm 208 240 VAC 60 HZ 1 OR 3 PHASE SOFT START REVERSING INVERTER DRIVE 43 RPM 375 RPM 60 G...

Page 8: ...abric softener as recommended by the manufacturer If liquid wash products are used in the detergent compartment they must be added at the beginning of the wash cycle If the machine is set for pre wash...

Page 9: ...will blink and will continue to blink during the programming mode 3 Press the DOWN or UP buttons to select which cycle to alter When the desired cycle number is displayed press START 4 The display sho...

Page 10: ...o exit the programming of a bath press the STOP button once and use the UP and DOWN keys select another bath Press the STOP button again to select a different cycle to change To end programming turn t...

Page 11: ...O d 2 Bleach Rinse 2 2 CH HI d 1 Rinse 3 2 CH HI d Rinse 4 Final Rinse 4 CH LO d 4 4 Sour Soft Cycle 2 Towels Pads Diapers Health Care Bath Bath Cycle Time min Water Temp Water Level Delay Fill Spin T...

Page 12: ...7 HH LO d 2 Bleach Rinse 3 2 CH HI d 1 Rinse 4 2 CH HI d Final Rinse 4 CH LO d 5 4 Sour Soft Cycle 4 Guest Laundry Hotel Motel or Health Care Bath Bath Cycle Time min Water Temp Water Level Delay Fil...

Page 13: ...ergent Rinse 2 2 HH HI d Rinse 3 7 HH LO d 2 Bleach Rinse 4 2 CH HI d 1 Final Rinse 2 CH LO d 5 Cycle 6 Colored Cotton Linen Food Beverage Bath Bath Cycle Time min Water Temp Water Level Delay Fill Sp...

Page 14: ...pid advance mode even if the key is turned to RUN and or removed Rapid advance cannot skip the final 1 minute tumble of the cycle and the door lock may remain activated for a couple minutes after the...

Page 15: ...washer Replace the pressure switch Turn on power to the washer See Note 6 Wrong washer size for drive type Turn off the power to the washer Check to ensure all the harnesses are properly connected to...

Page 16: ...cool Check the cooling fins of the drive to ensure proper airflow Check the wiring to the drive including the fan wiring If no problem is observed turn on power to the washer and test See Note If prob...

Page 17: ...se Water Supply 2 9990 027 011 Hose Water Supply 2 9379 197 001 Valve Shut Off 2 8641 242 000 Washer Inlet Hose 4 9565 003 001 Strainer Inlet Hose 8 Contact your distributor or Dexter Laundry Inc if a...

Reviews: