Monitor:
2.5” TFT, colour
Monitor resolution: 640 x 240 pixels
Line-out output:
1 Vpp / 600 Ohm
Dimensions:
approx. 100 x 180 x 34 mm incl.
wall bracket
Casing material:
indoor station: PC, ABS;
wall bracket: Aluminium
Weight:
approx. 306 g incl. wall bracket
Relative humidity:
20 - 80 %
Operating temperature: -10 °C to +50 °C
Application:
indoor use only
Model:
KSAFF1500150W1
Power supply:
100-240 V , 50/60 Hz, 0.6 A
Power output:
15 V
, 1.5 A
Application:
indoor use only
Wire cross section: 2 x 0.75 mm²
Supplied length:
15 m
Max. length:
75 m (min. 0.75 mm², copper)
The following instructions are provided for your safety
and satisfaction during operation of the device. Note that
non-observance of these safety instructions results in
significant risks of accident.
If this point is not heeded life and health is
endangered.
Non-observance of these instructions puts
property at risk of damage.
Optimum results will be achieved by observing
these instructions.
Do not leave small children unsupervised with the
device, packaging material or small parts. Otherwise
there is a risk of fatal injury due to choking or
suffocation.
Perform the connection and installation while the
mains power is disconnected! Otherwise there is a
risk of fatal injury due to electric shock.
Do not damage any gas, electricity, water or
telecommunication lines during drilling and fixing
work. Otherwise there are dangers of personal and
fatal injury and fire.
Treat the cables carefully. Lay these so that they
cannot be damaged and do not present any tripping
hazard. Fix the cables sufficiently. Do not pull the
cables over sharp edges and do not crush or crimp
them elsewhere. Otherwise there are dangers of
personal and fatal injury and fire.
Mains adapter
Connection cable
Safety instructions
Explanation of symbols and terms used:
Danger!
Attention!
Tip:
Danger!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Do not place the equipment near fire, heat or long
lasting high temperature effects of more than +50 °C.
Otherwise there is a risk of fatal injury due to fire.
Do not connect any external voltage to the connection
terminals. Otherwise there are dangers of personal
and fatal injury and fire.
Plug the mains adapter for the mains power
connection into the mains socket completely. Do not
touch it with wet hands. Otherwise there is a risk of
fatal injury due to electric shock.
Only operate the indoor station and the mains adapter
in dry areas. Do not expose them to dripping or splash
water. Only clean the equipment with a dry and, if
necessary slightly moist, cloth. Do not submerge the
equipment in water. Otherwise there is a risk of fatal
injury due to electric shock and fire.
Do not connect any damaged device (e.g. transport
damage) and disconnect the power supply
immediately in the case of damage. Unplug the mains
adapter from the mains socket. Arrange for the
damage to be repaired immediately by a specialist.
Otherwise there is a risk of fatal injury due to electric
shock.
Only operate the system with 15 V
DC from the
supplied power supply. Before connecting the power
supply to the mains, ensure that the mains current
complies with 230 V
AC, 50 Hz and is fitted with a
fuse according to local regulations.
Protect the equipment and the cables against strong
magnetic or electrical fields and against strong
mechanical loads and vibrations.
Only have repairs carried out by authorised and
trained qualified personnel. Otherwise there is a risk
of damage due to improper use and invalidation of the
warranty.
Observe the following points:
Protect the outdoor station as much as possible
against direct rainfall.
Mount the outdoor station at such a height that visitors
can comfortably reach the doorbell button and that the
face of the person ringing the bell is in the field of view
of the camera. Pay attention to the height of children
in doing so. The vertical detection angle of the camera
is approx. 48°.
The outdoor station is usually installed at the side of
the entrance door. Ensure that the face of the visitor
standing in front of the door can be seen on the
screen. The horizontal detection angle of the camera
Attention!
Planning the installation
Outdoor station:
GB / IE - 5