CONTROL/ DISPLAY PANEL
1. Important note – leave dehumidifier upright for at least 30 minutes before
operating.
2. Connect to power outlet and switch on. The indicator light will flash.
3. Press “ON/OFF” button once, “power” indicator will stay lit and the
“HUMIDITY%” display will show the room humidity level.
4. Press the “UP” or “DOWN” button to set the desired humidity value.
5. The dehumidifier will start to operate if the room humidity is higher than
set value. Otherwise it will not operate.
6. The 2-speed fan will start running, followed by the compressor after
approximately 3 minutes. This is a safety procedure.
7. HUMIDITY SETTING – Set Value moves by 5%
8. When Set Value is below 26%, the sign “CO” will appear on the screen
indicating Continuous Operation.
9. TIMER OFF- On running mode, press the Timer Off button to set Timer.
The Timer On LIGHT will flash and the Display Screen will show the
selected time. Press the “UP” or “DOWN” button to select the desired
time between “0” to “24” hours. The Buzzer will sound if there is no
operation for 5 minutes, and the TIMER OFF Light will turn on. Pressing
the TIMER OFF button again will cancel the setting.
10. Panel LOCK function – Press “UP” and “DOWN” button together for 2
seconds to lock the current setting. Screen will display “LC”. Repeat same
operation to release lock function.
11. Automatic DEFROST mode – When the room temperature is lower than
15*C or the evaporator coil temperature falls below 2*C for more than 10
minutes, the unit will automatically Defrost. In this mode, the compressor
will not run but the fan will continue running. The compressor remains off
until the coil temperature rises to 10*C for more than 10 minutes.
OPERATING INSTRUCTIONS
Removing Collected Water
1. When the water container is full and the unit stops operating, the water
FULL indicator light will LIGHT UP.
2. To empty water container, gently remove the container and empty the
water. Ensure components of water tank are correctly positioned.
3. The machine will re-start when the water container is placed in its
corrected position.
4. Do not remove the water container while the machine is still working. This
may cause water drip to wet your floor.
To install hose for Continuous Drainage
1. Locate stopper at LEFT side just above water tank cover door. Remove
stopper and replace with hose of approximately 13mm diameter.
2. Direct the hose to drain outlet or outside of room.
3. Ensure there is no kink or drastic bend on the hose.
4. CAUTION – Do NOT discard stopper. Replace with stopper each time the
hose is removed. (for water container collection mode)
MAINTENANCE
Important –
Ensure power plug is disconnected and unplug from electrical socket.
Do NOT use petrol, thinner or other chemical cleaners to clean unit.
Do NOT wash the unit directly under a tap or hose. This is unsafe and
electrical components may be damaged.
Cleaning Exterior Parts
Use a mild soap and water solution to clean exterior parts if necessary. Dry
after cleaning.
Cleaning the filter
The air filter is removable and washable. Remove the air filter located at the
back of the dehumidifier. The filter should be washed with mild soap solution
and water. Allow the air filter to dry before reinstalling. Torn or damaged
filters should be replaced. The filter should be cleaned at least once a month
or more frequently if used in dusty conditions.