De'WOODS MDH-30A User Manual Download Page 4

CONTROL/ DISPLAY PANEL

1. Important note – leave dehumidifier upright for at least 30 minutes before

operating.

2. Connect to power outlet and switch on. The indicator light will flash.

3. Press “ON/OFF” button once, “power” indicator will stay lit and the

“HUMIDITY%” display will show the room humidity level.

4. Press the “UP” or “DOWN” button to set the desired humidity value.

5. The dehumidifier will start to operate if the room humidity is higher than

set value. Otherwise it will not operate.

6. The 2-speed fan will start running, followed by the compressor after

approximately 3 minutes. This is a safety procedure.

7. HUMIDITY SETTING – Set Value moves by 5%

8. When Set Value is below 26%, the sign “CO” will appear on the screen

indicating Continuous Operation.

9. TIMER OFF- On running mode, press the Timer Off button to set Timer.

The Timer On LIGHT will flash and the Display Screen will show the

selected time. Press the “UP” or “DOWN” button to select the desired

time between “0” to “24” hours. The Buzzer will sound if there is no

operation for 5 minutes, and the TIMER OFF Light will turn on. Pressing

the TIMER OFF button again will cancel the setting.

10. Panel LOCK function – Press “UP” and “DOWN” button together for 2

seconds to lock the current setting. Screen will display “LC”. Repeat same

operation to release lock function.

11. Automatic DEFROST mode – When the room temperature is lower than

15*C or the evaporator coil temperature falls below 2*C for more than 10

minutes, the unit will automatically Defrost. In this mode, the compressor

will not run but the fan will continue running. The compressor remains off

until the coil temperature rises to 10*C for more than 10 minutes.

OPERATING INSTRUCTIONS

Removing Collected Water

1. When the water container is full and the unit stops operating, the water

FULL indicator light will LIGHT UP.

2. To empty water container, gently remove the container and empty the

water. Ensure components of water tank are correctly positioned.

3. The machine will re-start when the water container is placed in its

corrected position.

4. Do not remove the water container while the machine is still working. This

may cause water drip to wet your floor.

To install hose for Continuous Drainage

1. Locate stopper at LEFT side just above water tank cover door. Remove

stopper and replace with hose of approximately 13mm diameter.

2. Direct the hose to drain outlet or outside of room.

3. Ensure there is no kink or drastic bend on the hose.

4. CAUTION – Do NOT discard stopper. Replace with stopper each time the

hose is removed. (for water container collection mode)

MAINTENANCE

Important –
Ensure power plug is disconnected and unplug from electrical socket.
Do NOT use petrol, thinner or other chemical cleaners to clean unit.
Do NOT wash the unit directly under a tap or hose. This is unsafe and

electrical components may be damaged.

Cleaning Exterior Parts

Use a mild soap and water solution to clean exterior parts if necessary. Dry

after cleaning.

Cleaning the filter

The air filter is removable and washable. Remove the air filter located at the

back of the dehumidifier. The filter should be washed with mild soap solution

and water. Allow the air filter to dry before reinstalling. Torn or damaged

filters should be replaced. The filter should be cleaned at least once a month

or more frequently if used in dusty conditions.

Summary of Contents for MDH-30A

Page 1: ...setting high Wash air filter Remove obstacles or Relocate unit elsewhere Reset humidity setting on control panel Unit Noisy Water spill 1 Unit on uneven floor 2 Blocked filter Reposition unit Wash air filter E1 Temperature sensor error Replace sensor E2 Humidity sensor error Replace sensor E3 1 Motor fault 2 Compressor fault 3 Refrigerant leak Contact agent Technical Specifications Model No MDH 30...

Page 2: ... with the surface has humidity below 50 relative humidity The air is laden with moisture however the volume of moisture able to be carried at any given temperature is limited termed saturation vapor content Beyond this vapor returns to liquid water state from its gaseous state Based on this principle an air conditioner and a refrigerant dehumidifier cools the air lowering the saturation level and ...

Page 3: ...ert your finger or other foreign objects into grills or openings Take special care to warn children of these dangers 8 Always store the unit upright in order to maintain the compressor in proper working condition Leave the unit upright for at least 30 minutes before operating 9 Always unplug the unit before cleaning 10 Remove filter and clean with vacuum cleaner or wash with mild detergent Do NOT ...

Page 4: ...nning The compressor remains off until the coil temperature rises to 10 C for more than 10 minutes OPERATING INSTRUCTIONS Removing Collected Water 1 When the water container is full and the unit stops operating the water FULL indicator light will LIGHT UP 2 To empty water container gently remove the container and empty the water Ensure components of water tank are correctly positioned 3 The machin...