background image

Troubleshooting

Before contacting the manufacturer or agent for service, please check for
the following conditions:

Problems

Possible Cause

Corrective Action

Unit fails to

operate

1. Power “off”

2. Power Cord unplugged

3. Water tank not fitted

correctly

4. Water container is full

5. Defrosting

Switch Power “On”

Connect to electrical socket

Re-position water tank

Empty water tank

After defrosting , the unit

will restart.

Moisture

removal

decreased

1. Choked/ Dirty air filter

2. Obstacles in air outlet or

in air inlet

3. Humidity setting high

Wash air filter

Remove obstacles or

Relocate unit elsewhere

Reset humidity setting on

control panel

Unit Noisy

Water spill

1. Unit on uneven floor

2. Blocked filter

Reposition unit

Wash air filter

E1

Temperature sensor error

Replace sensor

E2

Humidity sensor error

Replace sensor

E3

1. Motor fault

2. Compressor fault

3. Refrigerant leak

Contact agent

Technical Specifications

Model No

MDH-30A

Power Supply

220-240V/ 1Ph/ 50Hz

Capacity (30*C80%RH)

30L/day

Power Input, Max.

460W

Compressor type

Rotary

Refrigerant

R410A

Water Tank capacity

6.5 Litres

Operating Temp.

5*C – 35*C

Net Weight

18 Kg.

Dehumidifier

Dehumidifier

model

model MDH-30A

Please read this instruction manual carefully before you use your dehumidifier,

Summary of Contents for MDH-30A

Page 1: ...setting high Wash air filter Remove obstacles or Relocate unit elsewhere Reset humidity setting on control panel Unit Noisy Water spill 1 Unit on uneven floor 2 Blocked filter Reposition unit Wash air filter E1 Temperature sensor error Replace sensor E2 Humidity sensor error Replace sensor E3 1 Motor fault 2 Compressor fault 3 Refrigerant leak Contact agent Technical Specifications Model No MDH 30...

Page 2: ... with the surface has humidity below 50 relative humidity The air is laden with moisture however the volume of moisture able to be carried at any given temperature is limited termed saturation vapor content Beyond this vapor returns to liquid water state from its gaseous state Based on this principle an air conditioner and a refrigerant dehumidifier cools the air lowering the saturation level and ...

Page 3: ...ert your finger or other foreign objects into grills or openings Take special care to warn children of these dangers 8 Always store the unit upright in order to maintain the compressor in proper working condition Leave the unit upright for at least 30 minutes before operating 9 Always unplug the unit before cleaning 10 Remove filter and clean with vacuum cleaner or wash with mild detergent Do NOT ...

Page 4: ...nning The compressor remains off until the coil temperature rises to 10 C for more than 10 minutes OPERATING INSTRUCTIONS Removing Collected Water 1 When the water container is full and the unit stops operating the water FULL indicator light will LIGHT UP 2 To empty water container gently remove the container and empty the water Ensure components of water tank are correctly positioned 3 The machin...

Reviews: