Dewetron HSI-LV Technical Reference Manual Download Page 9

9

HSI-LV

High speed isolated voltage amplifier

Bandwidth: 

2 Mhz

Input ranges: 

12 ranges (10 mV to 50 V)

Input type: 

AC and DC coupling software selectable

TEDS: 

Supports electronic data sheet sensors

Signal connection: 

   HSI-LV-B: 

Banana plugs 

   HSI-LV-BNC: 

BNC connector 

   HSI-LV-D: 

9-pin D-SUB connector

   HSI-LV-LEMO: 

7-pin LEMO connector

Module specifications

HSI-LV

Input ranges

10 mV, 20 mV, 50 mV, 100 mV, 200 mV, 500 mV, 1 V, 2.5 V, 5 V, 10 V, 25 V, 50 V

Button selectable ranges

10 mV, 50 mV, 200 mV, 1 V, 5 V, 10 V, 50 V

Rated input voltage

33 V

RMS

, 46.7 V

PEAK

, 70 V

DC

 according to EN-61010-1 and EN-61010-2-30

1 year accuracy

1)

Range 

Signal frequency 

Accuracy

  Bipolar

10 mV to 100 mV 

DC 

±0.02 % of reading ±60 µV

2.5 V 

DC 

±0.02 % of reading ±0.1 % of range

200 mV to 50 V 

DC 

±0.02 % of reading ±0.05 % of range

10 mV to 100 mV 

0.1 Hz to 5 kHz 

±0.1 % of reading ±30 µV

>5 kHz to 50 kHz

±0.4 % of reading ±30 µV

>50 kHz to 100 kHz

±(0.016*f) % of reading ±0.1 % of range

>100 kHz to 1 MHz

±(0.010*f) % of reading ±1 % of range

>1 MHz to 2 MHz

±(0.014*f) % of reading ±3 % of range

200 mV to 50 V 

0.1 Hz to 500 Hz 

±0.05 % of reading ±0.01 % of range

>500 Hz to 5 kHz

±0.1 % of reading ±0.05 % of range

>5 kHz to 50 kHz

±0.4 % of reading ±0.05 % of range

>50 kHz to 100 kHz

±(0.016*f) % of reading ±0.1 % of range

>100 kHz to 1 MHz

±(0.010*f) % of reading ±1 % of range

>1 MHz to 2 MHz

±(0.014*f) % of reading ±3 % of range

  Unipolar

10 mV to 100 mV 

DC 

±0.02 % of reading ±60 µV

200 mV to 50 V  

DC 

±0.02 % of reading ±0.08 % of range

Input coupling

DC or AC software selectable (1.5 Hz standard, custom on request down to 0.01 Hz)

Gain linearity

Typically 0.01 %; max. 0.04 % of  full scale

Gain drift range

Typically 10 ppm/°C (max. 30 ppm/°C)

Off set drift

10 mV to 200 mV: 

Typically 3 µV/°C

500 mV to 50 V:  

Typically 10 ppm of range/°C

Long term stability

100 ppm/sqrt (1000 hrs)

Input resistance

1 MOhm

Bandwidth (-3 dB)

2 MHz

Signal delay @ full bandwidth

approx. 405 ns

Filter selection

Push button or software

Filter

100 Hz, 300 Hz, 1 kHz, 3 kHz, 10 kHz, 30 kHz, 100 kHz, 300 kHz, 1 MHz, 2 MHz

2)

Filter type

Bessel or Butterworth 40 dB/dec

Filter characteristics

  100 Hz to 1 MHz

  2 MHz

Butterworth or Bessel 40 dB/dec (2

nd

 order; ±1.5 dB @ f

0

)

Butterworth 60 dB/dec (3

rd

 order; 0 to -3 dB @ 2 MHz)

Typical SFDR and SNR:

   20 mV

   1 V

   50 V

10 kHz bandwidth 

100 kHz  bandwidth 

 1 MHz  bandwidth 

 2 MHz bandwidth

SFDR           SNR 

SFDR             SNR 

 SFDR           SNR 

 SFDR           SNR 

88 dB           78 dB 

88 dB             71 dB   77 dB           60 dB 

 76 dB           56 dB

110 dB           98 dB  

110 dB             95 dB   93 dB           82 dB 

 84 dB           75 dB

110 dB           98 dB 

110 dB             95 dB   94 dB           82 dB 

 85 dB           75 dB

Typical CMRR

  50 Hz

  1 kHz

  10 kHz

  100 kHz

10 mV to 1 V range: 

2.5 V to 50 V range:

130 dB   

100 dB

120 dB   

60 dB

95 dB   

40 dB

75 dB   

20 dB

Input overvoltage protection

350 V

DC

Isolation voltage

1 kV

RMS 

3)

Sensor supply

±9 V (±1 %), 12 V (±5 %), 200 mA resettable fuse protected

4)

Output voltage

±5 V

Output resistance

10 Ohm

Maximum output current

5 mA

Output protection

Short to ground for 10 sec.

Power On default settings

Software programable

Power supply

±9 V

DC

 ±1 %

Power consumption

1.1 W without sensor supply

Special functions

Integrated temperature sensor

RS-485 interface

Yes

TEDS

Hardware support for TEDS (Transducer Electronic Data Sheet)

Supported TEDS chips

DS2406, DS2430A, DS2432, DS2433, DS2431

Supported MSI

MSI-V-ACC, MSI-V-RTD

1)

Conditions for accuracy: Module temperature is calibration temperature ±5 °C; humidity is 30 to 90 RH.

AC accuracy: the highest filter (2 MHz) has to be activated. f = signal frequency in kHz.

                                           For the 2 year accuracy multiply all % of range and % of reading values by 1.5.

2)

 2 MHz filter: exclusively for Butterworth 60 dB/decade - refer to filter specifications. Please consider possible bandwidth limitation of further components in the

   measuring chain, e.g. A/D card or signal conditioning mainframe.

3)

Although the rated input voltage is 33 V

RMS

, 46.7 V

PEAK

 or 70 V

DC

 according to EN-61010-1 and EN-61010-2-30, the galvanic isolation has been tested with 

   1 kV

RMS

 for 1 min.

4)

 Overall current should not exceed DEWE-30-xx maximum power.

continued on next page

nical Refe

450134 • DAQP/H

SI

/PAD Modules • Tech

 

rence Manual • Prin

t

ing version 2.3.4 • November 18, 2020

Summary of Contents for HSI-LV

Page 1: ...supply you with accurate complete and reproducible measurement results for your decision making Look forward to the easy handling and the flexible and modular use of your DEWETRON product and draw upo...

Page 2: ...protected by copyright All rights are reserved Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws All trademarks and regis...

Page 3: ...se of the information in this document Warranty Information A copy of the specific warranty terms applicable to your DEWETRON product and replacement parts can be obtained from your local sales and se...

Page 4: ...wing general safety precautions must be observed during all phases of operation service and repair of this product Failure to comply with these precautions or with specific warnings elsewhere in this...

Page 5: ...ained Keep away from live circuits Operating personnel must not remove equipment covers or shields Procedures involving the removal of covers or shields are for use by service trained personnel only U...

Page 6: ...com The telephone hotline is available Monday to Friday between 08 00 and 12 00 CET GMT 1 00 and Monday to Thursday between 13 00 and 17 00 CET For the Americas please contact DEWETRON Inc 2850 South...

Page 7: ...AQ series modules available The CAL KIT contains the required cables software and instructions General module specifications Module dimensions 20 x 65 x 105 mm 0 79 x 2 56 x 4 13 in W x H x D without...

Page 8: ...e FILTER button again Approx 3 seconds after the last key activity the information will be stored the LED stops flashing and shows the input range again CAUTION Power loss during this time leaves the...

Page 9: ...mV to 50 V DC 0 02 of reading 0 08 of range Input coupling DC or AC software selectable 1 5 Hz standard custom on request down to 0 01 Hz Gain linearity Typically 0 01 max 0 04 of full scale Gain drif...

Page 10: ...ications Please consider possible bandwidth limitation of further components in the measuring chain e g A D card or signal conditioning mainframe 3 Although the rated input voltage is 33 VRMS 46 7 VPE...

Page 11: ...9 9 pin DSUB OUTPUT CONNECTOR 10 mV 1 V 2 5 V 50 V Calibration memory o p t i o n a l 2 W D C D C 5 V 1 5 V HSI LV module resettable 200 mA fuse 3rd order Butterworth filter 2 MHz 2nd order lowpass f...

Page 12: ...filter is a 3rd order filter with a guaranteed 3 dB bandwidth of 2 MHz This filter structure is the same for all HSI modules Typical filter transfer function AC accuracy with activated filter With ac...

Page 13: ...r don t use the metal housing of D SUB connector HSI LV LEMO module Voltage measurement via LEMO cord 1 IN 2 IN 3 9 V 200 mA max 4 9 V 200 mA max 5 GND 6 12 V 200 mA max 15 V in conjunction with a DEW...

Page 14: ...EDS GND IN IN 9V 9V 4 20 mA 4 20 mA output 50 OHM 6 2 7 4 6 1 2 5 9 pin DSUB Connectors Sensor 2 wire 4 20 mA 7 pin LEMO GND IN IN 50 OHM 12V Output 6 2 7 4 6 1 2 5 9 pin DSUB Connectors Sensor 7 pin...

Page 15: ...ber States relating to electrical equipment designed for use within certain voltage limits amended by the directive 93 68 EEC 89 336 EEC Directive on the approximation of the laws of the Member States...

Page 16: ...C2 Notes...

Reviews: