10
Safety instructions
Your safety is our primary concern! Please be safe!
General safety and hazard warnings for all DEWETRON systems
Use this system under the terms of the specifications only to avoid any possible danger.
Maintenance will be executed by qualified staff only.
During the use of the system, it might be possible to access another parts of a more comprehensive
system. Please read and follow the safety instructions provided in the manuals of all other components
regarding warning and security advices for using the system.
With this product, only use the power cable delivered or defined for the host country.
DO NOT connect or disconnect sensors, probes or test leads, as these parts are connected to a voltage
supply unit.
The system is grounded via a protective conductor in the power supply cord. To avoid electric shocks,
the protective conductor has to be connected with the ground of the power network. Before connecting
the input or output connectors of the system, make sure that there is a proper grounding to guarantee
potential free usage. For countries, in which there is no proper grounding, please refere to your local
legally safety regulations for safety use.
DC systems: Every DC system has a grounding connected to the chassis (yellow/green safety banana
plug).
Please note the characteristics and indicators on the system to avoid fire or electric shocks. Before
connecting the system, please carefully read the corresponding specifications in the product manual.
The inputs are not, unless otherwise noted (CATx identification), for connecting to the main circuit of
category II, III and IV.
The power cord separates the system from the power supply. Do not block the power cord, since it has to
be accessible for the users.
DO NOT use the system if equipment covers or shields are removed.
If you assume the system is damaged, get it examined by authorised personnel only.
Any use in wet rooms, outdoors or in adverse environmental condition is not allowed!
Adverse environmental conditions are:
Moisture or high humidity
Dust, flammable gases, fumes or dissolver
Thunderstorm or thunderstorm conditions (except assembly PNA)
Electrostatic fields, et cetera.
The measurement category can be adjusted depending on module configuration.
Any direct voltage output is protected with a fuse against short cut and reverse-polarity, but is NOT
galvanically isolated (except it is explicit marked on the system).
The system must be connected and operated to an earthed wall socket at the AC mains power supply
only (except for DC systems).
Any other use than described above may damage your system and is attended with dangers like shortcut,
fire or electric shocks.
The whole system must not be changed, rebuilt or opened (except for changing DAQ, DAQP, PAD
modules).