Page 1: ...VIBRO KIT TECHNICAL REFERENCE MANUAL VIBRO KIT V20 2...

Page 2: ...8 4 5 Torsional vibration 20 5 Specifications HW v1 3 22 6 User interface FW v1 9 22 6 1 Manual mode 22 6 2 Ramp mode 23 6 3 Analog in mode 24 6 4 PWM in mode 24 7 Warranty information 25 7 1 Calibrat...

Page 3: ...VIBRO KIT TECHNICAL REFERENCE MANUAL 9 Documentation version history 29 VIBRO KIT V20 1 3 29...

Page 4: ...bols and formats will be used throughout the document Important It gives you important information about the subject Please read carefully Hint It gives you a hint or provides additional information a...

Page 5: ...ontrolled manually by a turn knob or you can completely define ramps cycles etc with the built in display Furthermore an external analog voltage or even PWM signal can be used to control the RPM Funct...

Page 6: ...he left side refers to the Tacho 1 output signal and right side refers to the Tacho 2 output signal Image 1 Vibro kit unit Counter input connectors on cable Pin Name Description 1 IN0 A Output A 2 IN1...

Page 7: ...sensor on the bottom side of the chassis for measuring signal of the striped tape on the rotating disc which is affixed on the shaft of the motor Please see chapter 3 3 1 Encoders to define which sens...

Page 8: ...el Button on the top serves as a ON OFF start button for the motor The front knob serves as a navigation knob for the Menu Display shows general values and motor options when Vibro kit is turned on Im...

Page 9: ...VIBRO KIT TECHNICAL REFERENCE MANUAL 3 3 4 Back panel Image 4 Back panel of drive part Power supply connector Pin Name Description 1 V Power supply 12V 36V 2 V Ground VIBRO KIT V20 1 9 29...

Page 10: ...the RPM of an internal motor with voltage signal Tacho 1 Out BNC female connector Measuring an output signal from an optical sensor that is integrated below the rotating disk Tacho 2 Out BNC female c...

Page 11: ...illation until the moving parts are equalized Black round plate has a white dotted strap on it which you can read with the tacho sensor Image 5 Flexible coupling on the right side The left encoder is...

Page 12: ...t time of the rising edge of the signal with an additional counter Image 7 Super counter Frequency super counter mode has many advantages over traditional counter measurements The problem with traditi...

Page 13: ...the setup of the channel where your encoder is connected Change the Basic application to the Sensor and choose the correct sensor from the dropdown list If your sensor is not on the list you can add i...

Page 14: ...le and Raw count on the same recorder When the Vibro Kit is running press Freeze and zoom into the signal You can see how DewesoftX interpolates the angle values and is not updated only when a new pul...

Page 15: ...ter Glue the accelerometer on the Vibro Kit Connect the accelerometer to the SIRIUS ACC module and enter the channel setup Select the IEPE mode if the sensor has a TEDS chip the sensitivity will be re...

Page 16: ...T TECHNICAL REFERENCE MANUAL Image 12 FFT analyser settings Enter the measure mode and add the FFT channel on a 2D graph Run the machine and observe the FFT Image 13 FFT math on 2D graph VIBRO KIT V20...

Page 17: ...rometer Glue the accelerometer on the Vibro Kit and connect it to the ACC module Connect encoder to the CNT module Open channel setup and set the acceleration sensor to IEPE mode and enter the correct...

Page 18: ...Image 15 Order tracking screen 4 4 Balancing Additional needed equipment SIRIUS with one ACC single plane balancing or two ACC modules dual plane balancing accelerometer single plane balancing or two...

Page 19: ...ght perform a trial run to get another unbalance vector From those two unbalanced vectors we calculate the correction mass that has to be added and the angle at which this should be added You can perf...

Page 20: ...put channel from the module Detailed description of the parameters and setting can be found here https training dewesoft com online course rotational and torsional vibration Image 18 Torsional vibrati...

Page 21: ...VIBRO KIT TECHNICAL REFERENCE MANUAL Image 19 Torsional vibration screen VIBRO KIT V20 1 21 29...

Page 22: ...024 P R Right Encoder 360 P R 6 User interface FW v1 9 After power up the Main Menu is shown Select one of the following modes 1 MANUAL 2 RAMP 3 ANALOG 4 PWM IN 6 1 Manual mode Set output voltage to s...

Page 23: ..._SW for 1sec Enabling the motor after the motor voltage has been set too high may result in input current limiter tripping resulting in system power down Disconnect and reconnect power supply to resta...

Page 24: ...uickly leading to input current limiter tripping Enable motor by holding RUN_SW for 1sec ON is displayed Input voltage is scaled 1 1 to motor output voltage Regardless of input voltage motor voltage i...

Page 25: ...alibrated at regular intervals The standard norm across nearly every industry is annual calibration Before your Dewesoft data acquisition system is delivered it is calibrated Detailed calibration repo...

Page 26: ...he logo When used in text representing the company product or technology name the sign is not used The Dewesoft triangle logo is a registered trademark but the sign is not used in the visual represent...

Page 27: ...Use this system under the terms of the specifications only to avoid any possible danger Read your manual before operating the system Observe local laws when using the instrument DO NOT touch internal...

Page 28: ...aged obviously or causes strange noises The system does not work anymore The system has been exposed to long storage in adverse environments The system has been exposed to heavy shipment strain Warran...

Page 29: ...ssness and in proper condition In order to maintain this condition and guarantee safety use the user has to consider the security advice and warnings in this manual EN 61326 3 1 2008 IEC 61326 1 appli...