Models

 

6080E 

6085E 

6100E 

 

6880E 

6885E 

 

Max. length (mm)

 

1950

 

1950

 

2000

 

Width (mm) 

700 

700 

800 

Min. 

– max. height (mm) 

620 - 1020 

620 - 1020 

620 - 1020 

Adjustment time (motor) (s)  

24 

24 

24 

Adjustment time, inclined 
position (motor) (s) 

20 

Weight (approx., depending on 
equipment) kg 

110 

120 

130 

Head part adjustment range  

+35° / -30 

+35° / -30 

+40° / -30 

3-sectioned head part adjustment 
range (option) 

 +35° / -20° 

 +35° / -20° 

Back part adjustment range 

+70° / -15° 

+70° / -15° 

Leg part adjustment range 

+20° / -85°  

+20° / -85° 

Adjustment range, inclined 
position 

   0° / +12° 

Max. patient weight (kg) 

220* 

220* 

200 

 

 

 

 

 

 

 

                Technical data subject to change 

 
* Weight load not for individual upholstery sections, but only centrally on the fixed lying surface above the 
telescopic column 

 

The motor is equipped with a thermal protective switch as standard. This causes the motor to cut out if the weight 
load is too extreme or the motor’s duty cycle (DC: 25 s/400 s) is exceeded. The table should be ready for use 
again after a 15-minute rest period. There is, therefore, no risk of overloading the motor.  
 
The mechanics of the tables have been designed with extensive safety margins in mind. The max. patient weight 
is provided with a 4-fold static safety factor, i.e. the design has been fully tested for a 4-fold load. 
 
 

4.2 Technical data for electric motor 

 

Manufacturer:   

Hanning Elektro-Werke GmbH & Co, D-33813 Oerlinghausen 

Type of motor:   

THS-3M 

Type of actuator: 

Brushless asynchronous industrial motor 

Mode of operation: 

Electromechanical linear motor with maintenance-free lifetime lubrication 

 

 

 

Intermittent duty 

– installed thermal switch 

 

 

 

Electronic activation with internal supply for the control element

 

 

 

 

Duty cycle (DC): 25 s / 400 s 

 

 

 

i.e. move the table for max. 25 seconds under nominal load, then observe a break of at  

 

 

 

least 400 seconds. 

Nominal voltage: 

220 

– 240 V, 1-50/60 Hz 

Nominal consumption / Current consumption: 

 

Models 6000E, 6001E, 6805E; 6070E, 6870E, 

 

             6080E, 6880E, 6100E:  

   480W - 2.1A 

 

Models 6050E, 6051E, 6810E:  

   950W - 4.1A 

 

Models 6075E, 6875E, 6085E, 6885E:                                        830W - 3.6A 

 

 

Protection class: 

I   connecting cable with protective conductor 

Protection rating: 

IPX0  

Degree of protection: 

 

The motor is maintenance free. 

 

The telescopic column is maintenance free. 

Summary of Contents for 6000E Series

Page 1: ...ntended purpose 2 1 5 Information on setup and use 3 1 6 Commissioning 3 1 7 Safety instructions 3 1 8 Model designation and type labelling 4 1 9 Meaning of the serial number 4 2 Operating manual 4 2...

Page 2: ...th the contents of these instructions for use before using the device We recommend that you keep these instructions for use near the device for future reference The device may only be used by authoris...

Page 3: ...y Remove the power cable from the film packaging on the underframe of the table and connect it properly to a permanently installed mains socket When routing the power cable make sure the cable cannot...

Page 4: ...attached to the underframe on one long side of the table It provides information about key table data The following symbols are listed there by way of example their meanings are Read the operating ma...

Page 5: ...as spring the head part must not be used for sitting Head part adjustment upwards and downwards positive and negative direction using a gas spring The head part is adjusted using a gas spring To opera...

Page 6: ...l lifting fixing mechanism is not controlled centrally a foot lever must be operated on each short side of the table in order to lower the table onto its feet or to place it on the castors This option...

Page 7: ...ort plate and removable upholstery The upholstery is attached to the frame using hook and loop tape on the sides To do this affix the tape on the underside of the frame The upholstery can be removed f...

Page 8: ...te rest period There is therefore no risk of overloading the motor The mechanics of the tables have been designed with extensive safety margins in mind The max patient weight is provided with a 4 fold...

Page 9: ...pid exchange of air is necessary To ensure this there are individual vent points on the underside of the upholstery which are hygienically sealed with special air compensation caps that assume a valve...

Page 10: ...on In the event of any abnormalities take the table out of service immediately and inform the operator Replace damaged or worn components immediately and do not use the table until it has been repaire...

Page 11: ...d to the manufacturer K H Dewert GmbH and to the competent authority of the Member State in which the user and or the patient resides Member State Competent authority Web Estonia Health Board Tervisea...

Page 12: ...s later on the no longer used product must be rendered unusable immediately e g by disconnecting the power cable Please observe the local regulations for waste disposal and preferably recycle the mate...

Page 13: ...fessionally trained persons who have been instructed in its use or who through experience with other similar medical devices have knowledge of its proper use taking into account possible hazards The d...

Page 14: ...All switches and supply lines undamaged Function check With electromotive adjustment Move all motors with the foot switch or the hand switch to both limit positions until automatic switch off to ensu...

Page 15: ...ntral locking system also the grub screws of switch levers Safe braking effect Check with locked brakes by pulling and pushing the table Structural inspection Check screw connections Retighten all scr...

Reviews: