5
English
plug must be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes and
ordinances.
WARNING:
Improper connection of the equipment-grounding
conductor can result in a risk of electrocution. Check with a qualified
electrician or service person if you are in doubt as to whether the
outlet is properly grounded. Do not modify the plug provided with the
product if it will not fit the outlet installed by a qualified electrician. Do
not use any type of adaptor with this product.
GrounD-FauLt cIrcuIt IntErruPtEr ProtEctIon
This pressure washer is provided with a Ground-Fault Circuit-
Interrupter (GFCI) built into the plug of the power supply cord. This
device provides additional protection from the risk of electric shock.
Should replacement of the plug or cord become necessary, use only
identical replacement parts that include GFCI protection.
Power Supply And Electrical Info
GrounD-FauLt cIrcuIt IntErruPtEr ProtEctIon
The pressure washer is factory-equipped with an electrical cord and
a Ground
Fault Circuit Interrupter (GFCI) power plug. This cord should
only be connected to an electrical outlet installed in accordance with
local safety regulations.
notE:
The power supply must be 120 V, 60 Hz and a minimum
15 amp dedicated circuit.
A. Inspect cord before using. Do not use if cord is damaged.
B. Keep all connections dry and off the ground.
C. Do not touch plug with wet hands.
D. The pressure washer is provided with a ground fault circuit
interrupter built into the power plug.
If replacement of the plug or cord is needed, use only identical
replacement parts. Contact customer service for proper replacement
parts.
WARNING:
Test GFCI before each use. DO NOT use pressure
washer if test below fails.
GFcI test Procedures:
1.
Plug GFCI into power receptacle.
N
M
Indicator light should illuminate.
2. Press test button (M). Light should turn
off.
3. Press reset button (N) for use. Indicator
light should illuminate.
Do not use if above test fails.
notE:
The GFCI must be reset each time
the pressure washer is connected to an
electrical outlet. Reset by simply pushing the
reset button on the GFCI power plug.
EXtEnsIon corDs
Use only extension cords that are intended for outdoor use. These
extension cords are identified by a marking “Acceptable for use with
outdoor appliances: store indoors while not in use”. Use only extension
cords having an electrical rating not less than the rating of the product.
Do not use damaged extension cords. Examine extension cord before
using and replace if damaged. Do not abuse extension cord and do
not yank on any cord to disconnect.
Keep cord away from heat and sharp edges. Always disconnect the
extension cord from the receptacle before disconnecting the product
from the extension cord.
When using an extension cord, observe the specification below:
cable Length
Wire Gauge
Up to 25 ft. (7.5 m)
12 AWG Outdoor
Summary of Contents for DXPW1500E