E
ng
lish
3
Specifications
CONTENTS
WARNINGS ........................................................................ 2-3
HEATER SPECIFICATIONS ................................................... 3
OPERATING PRECAUTIONS ................................................ 4
SAFETY PRECAUTIONS ....................................................... 4
ODOR FADE WARNING ..................................................... 5-6
OPERATING INSTRUCTIONS ............................................... 6
MAINTENANCE, STORAGE AND SERVICE ......................... 7
WIRING DIAGRAMS .............................................................. 8
PARTS LISTS/EXPLODED VIEWS .................................... 9-12
WARRANTY ......................................................................... 13
INSTRUCTIONS FOR ORDERING PARTS .......................... 13
WARNING: RISK OF FIRE OR EXPLOSION
• Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
• WHAT TO DO IF YOU SMELL GAS:
• Open windows.
•
DO NOT
try to light any appliance.
•
DO NOT
operate any electrical switches.
•
DO NOT
use any telephone in building. Immediately call the
local gas supplier from an outside telephone. Follow the gas
supplier’s instructions.
•
DO NOT
touch any electrical switch; do not use any phone in your
building.
• If you cannot reach your gas supplier, call the Fire Department.
Model:
DXH65FAV
DXH85FAV
Rating:
30,000 - 65,000 Btu/Hr
50,000 - 85,000 Btu/Hr
(8.8 – 19.0 kW)
(14.6 – 25.0 kW)
Fuel Consumption:
1.4 – 2.5 #/hr
2.3 – 3.9 #/hr
(.64 – 1.1 kg/hr)
(1.04 – 1.77 kg/hr)
Fuel Orifice Size
0.50 mm
0.60 mm
SPECIFICATIONS
Type of Gas: ..............For use with Propane Only
Gas Supply Pressure
to regulator .............Max.: Bottle Pressure
to regulator .............Min.: 5 psig (34.5 kPa)
regulator out ..........27.5" W.C. (6.84 kPa)
Electrical Input: ..........115V, 60 Hz, 1Ø, 3a
Min. Operating Voltage: 100V
Ignition: ......................Direct Spark
Primary
Flame Control: .........Thermocouple Operated Gas Valve
High Temperature
Control: ....................240°F (116°C)
Min. Ambient Temp. Rating 0°F (-17.8°C)
Summary of Contents for DXH65FAV
Page 10: ...English 10 DXH65FAV ...
Page 12: ...12 English DXH85FAV ...
Page 14: ......
Page 24: ...Français 10 DXH65FAV ...
Page 26: ...12 Français DXH85FAV ...
Page 37: ...Español 10 DXH65FAV ...
Page 39: ...12 Español DXH85FAV ...