19
E N G L I S H
IMPACT WRENCH
DW292, DW294
WARNING:
●
The declared vibration emission level
represents the main applications of the
tool. However, if the tool is used for
different applications, with different
accessories or poorly maintained, the
vibration emission may differ. This may
signi
fi
cantly increase the exposure level
over the total working period.
●
An estimation of the level of exposure
to vibration should also take into
account the times when the tool is
switched off or when it is running but
not actually doing the job. This may
signi
fi
cantly reduce the exposure level
over the total working period.
●
Identify additional safety measures to
protect the operator from the effects of
vibration, such as: maintain the tool and
the accessories, keep the hands warm,
organisation of work patterns.
De
fi
nitions: Safety guidelines
The de
fi
nitions below describe the level of severity
for each signal word. Please read the manual and
pay attention to these symbols.
DANGER:
Indicates an imminently
hazardous situation which, if not
avoided, will result in death or serious
injury.
WARNING:
Indicates a potentially
hazardous situation which, if not
avoided, could result in death or serious
injury.
CAUTION:
Indicates a potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury.
Congratulations!
You have chosen a D
E
WALT tool. Years of
experience, thorough product development and
innovation make D
E
WALT one of the most reliable
partners for professional power tool users.
Technical data
DW292
DW294
Voltage V
230
230
(U.K. & Ireland only)
V
230/115
-
Type
2
2
Power input
W
710
710
No-load speed
min
-1
2,200 2,200
Socket size
1/2"
3/4"
Weight kg
3.2
3.2
L
PA
(sound pressure)
dB(A)
99 99
K
PA
(sound pressure
uncertainty)
dB(A)
3 3
L
WA
(sound power)
dB(A)
107 107
K
WA
(sound power uncertainty) dB(A)
4.6 4.6
Vibration total values (triax vector sum) determined according to
EN 60745:
Vibration emission value (ah)
a
h
=
m/s²
8.0
8.0
Uncertainty K =
m/s²
1.5
1.5
Fuses:
Europe
230 V tools 10 Amperes, mains
U.K. & Ireland
230 V tools 13 Amperes, in plugs
U.K. & Ireland
115 V tools 16 Amperes, mains
The vibration emission level given in this
information sheet has been measured in
accordance with a standardised test given in
EN 60745 and may be used to compare one tool
with another. It may be used for a preliminary
assessment of exposure.
Summary of Contents for DW292
Page 1: ...DW292 DW294 www eu ...
Page 3: ...1 A 4 3 2 1 8 7 ...
Page 4: ...2 B C 4 3 6 5 4 3 6 5 ...
Page 5: ...3 D 2 E ...
Page 102: ...100 ...
Page 103: ...101 ...