7
E
Error Codes
If
INFO
appears on the display window with a
Code
number, perform the corresponding
Corrective
Action.
Code
Description
Corrective Action
101
Received Signal Too Weak,
Measuring Time Too Long
Use the target plate or change the target surface.
102
Received Signal Too High
Target is too reflective. Use the target plate or change the
target surface.
201
Too Much Background Light
Reduce the background light on the target area.
202
Laser Beam Interrupted
Remove the obstacle and repeat the measurement.
203
Insufficient Power
Replace the batteries.
301
Temperature Too High
Allow the device to cool down to a temperature within the
specified
Operating
Temperature
Range
.
302
Temperature Too Low
Allow the device to warm up to a temperature within the
specified
Operating
Temperature
Range
.
401
Hardware Error
Switch the device on/off several times. If the error still
occurs, return the defective device to the Service Center or
distributor. Refer to the
Warranty
.
402
Unknown Error
Contact the Service Center or distributor. Refer to the
Warranty
.