Operation Modes
OPERATION MODE
LED INDICATION
ACTION
Pack Charging
_ _ _ _ _
leave pack in charger
Pack Charged
___________
goes into equalization & maintenance
Temperature Delay
_ . _ . _ .
charger waits for battery to cool down
Defective Pack
. . . . . . . . .
contact DEWALT service
Tune-up Mode
__ ... _ _ _
only use occasionally (4h charge mode)
Problem Powerline
.. .. .. .. ..
no charge, resumes when voltage is
within 195-265V/100-140V(UK)
•
Equalization charge
interval provides an additional charge to those cells in the
battery’s series string that may have less charge than the others at the termination
of the fast charge cycle. The lower current (83mA) is prevents cell damage during
this overcharge period.
•
Maintenance mode
current (63mA) overcomes self discharge of the cells in the
battery pack. Battery pack removal stops all charging and returns the charger to
standby mode.
•
Tune up mode
combines fast charge, equalization, maintenance into a 4h charge