Technical data
DC352
Voltage V
DC
18
Power W
390
No-load speed
min
-1
3200
Blade diameter
mm
165
Maximum Depth of cut
90˚ (without guide rail)
mm
60
90˚ (with guide rail)
mm
55
Blade bore
mm
20
Bevel angle adjustment
47˚
Weight (without battery pack) kg
4.6
Battery pack
DE9503
Battery type
NiMH
Voltage V
DC
18
Capacity Ah
2.6
Weight kg
1.0
Charger
DE9116
Mains voltage
V
AC
230
Battery type
NiCd/NiMH
Approx. charging time
min
30
Weight kg
0.52
Fuses:
Europe
230 V tools
10 Amperes, mains
U.K. & Ireland
230 V tools
13 Amperes, in plugs
The vibration emission level given in this information
sheet has been measured in accordance with a
standardised test given in EN 60745 and may be
used to compare one tool with another. It may be
used for a preliminary assessment of exposure.
WARNING:
The declared vibration
emission level represents the main
applications of the tool. However if the
tool is used for different applications,
with different accessories or poorly
maintained, the vibration emission may
differ. This may significantly increase the
exposure level over the total working
period.
An estimation of the level of exposure to
vibration should also take into account
the times when the tool is switched off
or when it is running but not actually
doing the job. This may significantly
reduce the exposure level over the total
working period.
Identify additional safety measures to
protect the operator from the effects of
vibration such as: maintain the tool and
the accessories, keep the hands warm,
organisation of work patterns
.
DC352
L
pA
(sound pressure)
dB(A
91
K
pA
(sound pressure uncertainty) dB(A)
4.8
L
WA
(acoustic power)
dB(A)
102
K
WA
(acoustic power uncertainty) dB(A)
4.8
Vibration total values (triax vector sum)
determined according to EN60745:
DC352
Vibration emission value = 1.8 m/s²
Uncertainty K = 1.5 m/s²
Defi nitions: Safety Guidelines
The definitions below describe the level of severity
for each signal word. Please read the manual and
pay attention to these symbols.
DANGER:
Indicates an imminently
hazardous situation which, if not avoided,
will
result in
death or serious injury
.
WARNING:
Indicates a potentially
hazardous situation which, if not
avoided,
could
result in
death or
serious injury
.
CAUTION:
Indicates a potentially
hazardous situation which, if not
avoided,
may
result in
minor or
moderate injury
.
CAUTION:
Used without the safety alert
symbol indicates a potentially hazardous
situation which, if not avoided,
may
result in
property damage
.
Denotes risk of electric shock.
Denotes risk of fire.
Summary of Contents for dc352
Page 1: ...DC352 www eu ...
Page 3: ...1 q n Figure 1 c b a h d f g e j j k l m n Figure 2 A B Figure 3 p o ...
Page 4: ...2 Figure 4 Figure 5 r s k u t v 2 3 mm 2 3 mm l m ...
Page 5: ...3 Figure 6 f Figure 7 d h c ...
Page 6: ...4 Figure 8 Figure 9 w aa w bb y z ...
Page 167: ......
Page 168: ......
Page 169: ......