17
English
CoDe
PoSSIBLe CAuSe
PoSSIBLe SoLutIon
15
Extension cord is wrong length or gauge
Check for proper gauge wire and cord length. See
extension Cords under
Installation
.
16
Loose electrical connections
Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
17
Possible defective motor.
Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
18
Fuse blown, circuit breaker tripped
1. Check fuse box for blown fuse and replace as necessary.
Reset circuit breaker. Do not use a fuse or circuit
breaker with higher rating than that specified for your
particular branch circuit.
2. Check for proper fuse. Use only a time delay fuse.
3. Check for low voltage conditions and/or proper extension
cord.
4. Disconnect the other electrical appliances from circuit or
operate the compressor on its own branch circuit.
19
Tank pressure exceeds pressure switch
cut-in pressure
Motor will start automatically when tank pressure drops
below
cut-in pressure of pressure switch.
Summary of Contents for D2002M