OUTDOOR UNIT SPECIFICATIONS
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/ circuit breakers
and wires in accordance with all national and/or local electrical codes. Use copper wire only.
Part Number
GSX14018
(CZ)
GSX14024
(HH)
Cooling Capacity, BTUH
18,000
24,000
Compressor
R.L. Amps
L.R. Amps
Decibels
Low Pressure Switch
Open
Close
High Pressure Switch
Open
Close
6.0
37.5
75
22 PSIG
50 PSIG
6 1 0 P S I G
4 2 0 P S I G
7.7
38.0
74
22 PSIG
50 PSIG
6 1 0 P S I G
4 2 0 P S I G
Condenser Fan Motor
Horsepower
F.L. Amps
1/8
0.65
1/8
0.7
Refrigeration System
Line Size
Liquid Line, Inches O.D.*
Suction Line, Inches O.D.*
Connection Size
Liquid Valve Size (OD)
Suction Valve Size (OD)
Valve Type
Refrigerant Charge
Included Piston
Low Pressure Switch
High Pressure Switch
3/8"
3/4"
3/8"
3/4"
sweat
68
0.051
94 psi
150 psi
3/8"
3/4"
3/8"
3/4"
sweat
72
0.057
94 psi
150 psi
Electrical Data
Voltage-Phase (60 Hz)
Min/Max Volts
Max. Overcurrent Protection
Minimum Circuit Ampacity
(1)
208/230-1
197/253
15 A
8.2 A
08/230-1
197/253
15 A
10.3 A
Weights
Equipment Weight
Shipping Weight
102 lb
117 lb
126 lb
141 lb
W x D x H
Inches
26 x 26 x 27½
cm
66 x 66 x 70
Copyright © 2019 DewAir Corporation
12
RHC18O-IM v2.11 Sep 4, 2019
(1)
Wire size should be determined in accordance with National Electrical
Codes; extensive wire runs will require larger wire sizes.
(2)
Maximum Overcurrent Protection Device:
MUST
use Time Delay
Fuses or HACR type Circuit Breaker of the same size as noted.
D
W
H