- 11 -
5. OPERATION
5.1 CONTROL PANEL
POWER button
Press the power button to turn on the machine, the running indicator lights will
be on and the machine will enter common mode automatically
Press the power button again to turn off the machine, the running indicator
lights will be off and the compressor will stop immediately,the fan will also stop
after 30 seconds later.
MODE button
The machine has 3 modes : Common mode , Continuously dehumidify mode,
Sleeping mode
Press mode button to switch from one to another, the corresponding mode
indicator light will be on after you choose one mode
●
Common mode
:
Under this mode, the default humidity setting data is 50%RH
When room humidity ≥ setting humidity data +3%, the fan will start working and
compressor will start working after 3 seconds later.
When room humidity ≤ setting humidity data -3%, the compressor will stop
working and fan will stop working after 30 seconds later.
The fan speed setting function and humidity setting function is effective , you
can set fan speed and humidity data under this mode