Technical specifications
- condenser studio microphone
- pressure gradient transducer
- gold-plated 34 mm diaphragm
- gold-plated XLR connector
- suitable for vocal and instrument recording
- -10 dB pad, for clear capture of loud sources, such as drums
- high-pass filter, to eliminate low frequency rumble and turbulence
3 selectable pick-up patterns
- cardioid
- figure-eight
- omnidirectional
Polar pattern: cardioid
- frequency response: 20 Hz – 20 kHz
- sensitivity: -31 dB (+/- 2 dB) at 0 dB=1V/Pa at 1 kHz
- output impedance: 150 Ohms (+/- 30%) at 1 kHz
- load impedance: 1000 Ohms
- self noise: 14 dB (A-weighted)
- maximum SPL: 130 dB (at 1 kHz, < 1% T.H.D.)
- signal/noise ratio: 80 dB
- +48V phantom power required
- electrical current: 3 mA
- -10 dB pad (increases the max. input SPL from 130 to 140 dB)
Polar pattern: figure-eight
- frequency response: 20 Hz – 20 kHz
- sensitivity: -34 dB (+/- 2 dB) at 0 dB=1V/Pa at 1 kHz
- output impedance: 200 Ohms (+/- 30%) at 1 kHz
- load impedance: 1000 Ohms
- self noise: 15 dB (A-weighted)
- maximum SPL: 130 dB (at 1 kHz, < 1% T.H.D.)
- signal/noise ratio: 79 dB
- +48V phantom power required
- electrical current: 3 mA
- -10 dB pad (increases the max. input SPL from 130 to 140 dB)
Polar pattern: omni-directional
- frequency response: 20 Hz – 20 kHz
- sensitivity: -35 dB (+/- 2 dB) at 0 dB=1V/Pa at 1 kHz
- output impedance: 200 Ohms (+/- 30%) at 1 kHz
- load impedance: 1000 Ohms
- self noise: 16 dB (A-weighted)
- maximum SPL: 130 dB (at 1 kHz, < 1% T.H.D.)
- signal/noise ratio: 78 dB
- +48V phantom power required
- electrical current: 3 mA
- -10 dB pad (increases the max. input SPL from 130 to 140 dB)
Included shock mount
- shock mount reduces unwanted noise
- padded microphone holder, prevents scratches
- angle adjustable
- 5/8” thread
Any information and illustrations shown in this user manual are subject to change without further notice.
User manual version: 1.0
Creation date + author initials: 27-03-2014 RV Revision date + author initials: 27-03-2014 RV