© 2012 ITW Finishing Systems and Products
13
Parts Replacement/
Maintenance
SUCTION CUP LID
1. Remove drip free diaphragm (54).
Clean or replace. Make sure the vent
hole is kept clear. (see fig 34).
2. Remove cup lid gasket (53)
(see fig 35).
3. Make Sure the vent hole in the lid (56)
is clean and not blocked. (see fig 36).
4. It is recommended to replace the cup
gasket (53) with a new one to avoid
cup leaks (see fig 35).
5. Re-fit the drip free diaphragm. Position
the vent hole in the diaphragm 180°
away from the lid vent hole (see fig 34)
Chart 1
– Air Caps
NOTE: When removing air cap from retaining ring, don’t remove the Slip Ring (2) or Retaining Ring Seal (5) from
the Retaining Ring. Damage to the parts may occur. Slip ring and Retaining Ring seal are not available as
replacements. Simply wipe parts clean and reassemble with new or clean air cap.
Chart 2
– Fluid Nozzle Range & Fluid Needle
SPRAY GUN
PART No. ON FLUID NOZZLE
PART No. NEEDLE
PROPL (Pressure Feed)
PRO-205-085-K
PRO-320-085-10-K
PRO-205-10-K
PRO-205-12-K
PRO-320-12-14-K
PRO-205-14-K
PROSL (Suction Feed)
PRO-200-16-K
PRO-325-K
PRO-200-18-K
PRO-200-20-K
NOTE: When replacing the fluid nozzle or fluid needle, replace both at the same time. Torque to 18
–20 Nm (160–
180 lbs.in). Do not over tighten the fluid nozzle. Use SN-28 (59) 10mm Spanner supplied with the gun and check
with a torque wrench.
PART No. FOR AIR
CAP
TECHNOLOGY
MARKING
ON AIR CAP
FLUID FEED
RECOMMENDED
INLET
PRESSURE (bar)
AIR FLOW
(L/min) @
2 bar
PRO-102-HV30-K
HVLP
HV30
Suction/Pressure
1.75
465
PRO-102-TE10-K
High Efficiency
TE10
Suction/Pressure
2.0
275
PRO-102-TE20-K
High Efficiency
TE20
Suction/Pressure
2.0
350
PRO-102-TE30-K
High Efficiency
TE30
Pressure Only
2.0
300
PRO-102-TE40-K
High Efficiency
TE40
Pressure Only
2.0
365