Installation

 

 

Important:

  To  ensure  that  this  equipment  reaches  you  in  first  class  condition,  protective  coatings 

have been used. 

Flush the equipment through with a suitable solvent before use. 

1.  Attach  air  hose  to  connector  (19).  Recommended  hose  size  8  mm  bore.  The  hose  must  be 

conductive  and  electrical  bond  from  the  spray  gun  to  earth  should  be  checked  with  an 
ohmmeter. A resistance of less than 10

6

Ω is recommended. 

2.  Air supply should be filtered and regulated.

 

 

Operation 

 

1.  Mix coating material to manufacturers instructions. 
2.  Turn needle adjusting screw (18) counter-clockwise until first thread shows. 
3.  Turn pattern valve (10) counter-clockwise to fully open. 

4. 

Adjust inlet air pressure to give 2.4 bar (35 psi) at the gun inlet with the gun triggered.

 (pressure 

gauge attachment shown under Accessories is recommended for this). 

5.  Test spray. If the finish is too dry, reduce air flow by reducing inlet pressure. If finish is too wet, 

reduce fluid flow  by turning needle screw (18) clockwise. If atomisation is too coarse, increase 
inlet air pressure. If too fine, reduce inlet pressure. 

6.  The pattern size can be reduced by adjusting valve (10). 
7.  Hold gun perpendicular to surface being sprayed. Arcing or tilting may result in uneven coating. 
8.  The recommended spray distance is 150-200 mm (6”-8”). 
9.  Spray edges first. Overlap each stroke a minimum of 50%. Move gun at a constant speed. 
10. Always turn off air supply and relieve pressure when gun is not in use. 

 

Preventative Maintenance 

 

1.  Turn  off  air  supply  and  relieve  pressure  in  the  airline  or,  if  using  QD  system,  disconnect  from 

airline.  

2.  Empty coating material into a suitable container and clean the gun and cup, preferably in a gun 

wash machine. 

3.  IMPORTANT–  the  cup  must  not  be  cleaned  or  rubbed  with  a  dry  cloth  or  paper.  It  is 

possible to generate a static charge by rubbing which, if discharged to an earthed object, 
could  create  an  incendive  spark  and  cause  solvent  vapours  to  ignite.  Only  use  a 
dampened  cloth  or  antistatic  wipes  if  additional  cleaning  is  required  within  a  hazardous 
area.  

4.  Remove air cap (2) and clean. If any of the holes in the cap are blocked with coating material, 

only  use  the  cleaning  kit  KK-4584  which  has  the  correct  tools  for  this  (see  Accessories)  or,  a 
toothpick  to  clean.  Using  any  other  tool  could  damage  the  cap  and  produce  distorted  spray 
patterns. 

5.  Ensure the tip of the nozzle is clean and free from damage. Build-up of dried paint can distort the 

spray pattern. 

6.  Lubrication – Trigger stud (24), needle (16) and air-valve spindle (13) should be oiled each day. 
 

Summary of Contents for FLG-G5

Page 1: ...SB E 2 790 ISS 06 Operation Manual FLG G5 Transtech Gravity Spray Gun EN ...

Page 2: ...el These guns are not designed for use with highly corrosive and or abrasive materials and if used with such materials it must be expected that the need for cleaning and or replacement of parts will be increased If there is any doubt regarding the suitability of a specific material contact your local Distributor or Finishing Brands UK Limited direct Specification Air supply connection Universal BS...

Page 3: ...material before spraying If in doubt contact your material supplier The use of respiratory protective equipment is recommended at all times The type of equipment must be compatible with the material being sprayed Always wear eye protection when spraying or cleaning the spray gun Gloves must be worn when spraying or cleaning the equipment Training Personnel should be given adequate training in the ...

Page 4: ...1 14 Air valve spring 1 15 Air valve bushing 1 16 SGK 0414 SGK 0418 SGK 0420 Fluid needle 1 4mm Fluid needle 1 8mm Fluid needle 2 0mm available separately 1 17 Fluid needle spring 1 18 Fluid adjustment knob 1 19 Nipple 1 20 Retaining ring 1 21 Air adjusting valve head 1 22 Air adjusting valve assembly 1 23 Retaining ring 1 24 Trigger pin assembly 1 25 Trigger 1 26 Fluid nipple 1 28 KGP 5 K5 Filter...

Page 5: ...ards or other normative documents BS EN 292 1 PARTS 1 2 1991 BS EN 1953 1999 and thereby conform to the protection requirements of Council Directive 98 37 EC relating to Machinery Safety Directive and EN 13463 1 2001 council Directive 94 9 EC relating to Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres protection level II 2 GX This product also complies with t...

Page 6: ...erpendicular to surface being sprayed Arcing or tilting may result in uneven coating 8 The recommended spray distance is 150 200 mm 6 8 9 Spray edges first Overlap each stroke a minimum of 50 Move gun at a constant speed 10 Always turn off air supply and relieve pressure when gun is not in use Preventative Maintenance 1 Turn off air supply and relieve pressure in the airline or if using QD system ...

Page 7: ...l 11 to service tool 9 Fit new seal to gun body and press firmly to ensure seal is engaged 10 Fit new valve seat 12 to service tool and fit valve seat into gun body 11 Remove rear sir valve seal 11 from housing 15 with a hooked instrument 12 Fit new seal to service tool and fit deal to housing 15 13 Replace spindle 13 14 Replace valve spring 14 screw in housing 15 and tighten 15 Screw reverse end ...

Page 8: ... BH11 9LH UK Tel No 44 0 1202 571111 Fax No 44 0 1202 581940 Website address http www finishingbrands eu Registered office Finishing Brands UK Limited 400 Capability Green Luton Bedfordshire LU1 3AE UK Registered in England No 07656273 Vat No GB 113 5531 50 Finishing Brands UK Limited ...