background image

SB-6-224-A  (11/2016)

1 / 2

SERVICE BULLETIN

HAR-680 80 CFM REGULATOR

DESCRIPTION
These units are designed to remove 

water and dirt particles.

SPECIFICATIONS:
Air Inlet: 

1/2 NPT (female)

Air Outlet HAF-580: 3/8 NPT (female) 

Air Outlet HAR-680: 1/4 NPSM (male)
Air Capacity: 

80 CFM filter 

 

50 CFM regulator

Max. Pressure: 

150 PSI

Max. Temp.: 

150° F

Filter Size: 

5 micron

Risk of personal injury.

Risk of property damage.

RELEASE ALL AIR PRESSURE  

BEFORE SERVICING.

This product is specifically designed 

for compressed air service. Use with 

any other fluid (liquid or gas) is a 

misapplication. For example, use 

with or injection of certain hazard-

ous gases in the system (such as 

oxygen or liquid petroleum gas) 

could be harmful to the unit or 

result in a combustible condition 

that may cause  fire or explosion. 

Manufacturer’s warranties are void 

in the event of misapplication and 

manufacturer assumes no responsi-

bility for any resulting loss.

INSTALLATION
1. Assemble unit (refer to Figure1).
2. Install with the air flowing into the 

top of the filter.

3. Install in a vertical position.

OPERATION
1. Turn the regulator’s handle clock-

wise to increase pressure.

2. To decrease pressure, turn the 

handle counterclockwise.

3. Relieve downstream pressure by 

triggering spray gun or tool.

MAINTENANCE
1. Drain filter daily.
2. Depressurize before replacing 

filter element.

3. Replace element at least once per 

year.

SERVICE PARTS
See Parts List, page 2.

WARRANTY
This product is covered by DeVil-

biss’ one year limited warranty. See  

SB-1-000 which is available upon  

request.

FIGURE 1

Only on  

HAR-680