Cobra 2 Automatic Spraygun 

Important 

Read and follow all instructions and Safety Precautions before using this 

equipment 

 

CHARACTERISTICS 

This automatic spray gun complies to ATEX regulations 94/9/EC, protection level II 2 G X, suitable to 
use in Zones 1 & 2. 
This 

Cobra 2

 is a production spray gun suitable for use with automatic and semi-automatic machines 

in conventional, HVLP or Trans-Tech applications.  
Cobra 2 has a ¼ turn Quick detachable device, so to reduce maintenance & set up time (SMED). 
To handle a wide range of coating materials the fluid passages are manufactured from high grade 
stainless steel. 
This spray gun is supplied with an indexed air cap. You can leave your air cap capable of free 
rotation by removing the indexed plastic ring which is located by 2 pins on the air cap. 
Pressure feed material supply can be re-circulating or direct.  
The needle adjustment knob has 18 ratchet positions, allows fine and accurate fluid flow control. 
 

SPECIFICATIONS & MATERIALS OF CONSTRUCTION 

 

Thread Pressure 

Fluid inlet & recirculation 

“P” 

1/8 BSP 

Max 7 Bar 

Air inlet (Atom+Fan) 

“A”  “F” 

1/8 BSP 

Max 7 Bar 

Cylinder/trigger “C” 

1/8 BSP 

4 to 7 bar 

Maximum temperature in use 

40° C 

Spray gun weight 

950 g 

Gun body 

Aluminium hard anodized 

Tip / Needle / Spray head/ Base plate 

Stainless steel 303 

 
 

 

EC Declaration of Conformity 

We, 

ITW Finishing UK, Ringwood Rd, Bournemouth, Dorset, BH11 9LH, UK

, as the 

manufacturer of the 

Spray gun model COBRA 

, declare, under our sole responsibility that the 

equipment to which this document relates is in conformity with the following standards or other 
normative documents: 

BS EN 292-1 PARTS 1 & 2: 1991, BS EN 1953: 1999; 

and thereby conform to the protection 

requirements of Council Directive 

98/37/EEC 

relating to 

Machinery Safety Directive

and; 

EN 13463-1:2001,

 council Directive 

94/9/EC 

relating to 

Equipment and Protective Systems 

intended for use in Potentially Explosive Atmospheres protection level II 2 G X

 

B. Holt

, General Manager  

24

th

 April 2007 

 

 

ITW Finishing Systems and Products reserve the right to modify equipment specification without prior notice. 

 

Summary of Contents for Cobra 2

Page 1: ...1 SB E 2 CBA2 ISS 09 Operation Manual Cobra 2 Automatic Spray Gun EN...

Page 2: ...rate fluid flow control SPECIFICATIONS MATERIALS OF CONSTRUCTION Thread Pressure Fluid inlet recirculation P 1 8 BSP Max 7 Bar Air inlet Atom Fan A F 1 8 BSP Max 7 Bar Cylinder trigger C 1 8 BSP 4 to...

Page 3: ...spraying If in doubt contact your material supplier The use of respiratory protective equipment is recommended at all times The type of equipment must be compatible with the material being sprayed Alw...

Page 4: ...Small Piston 2 15c S 28224X K4 O ring Kit of 4 2 15d S 28225X K2 O Ring Kit of 2 1 16 S 28219X K4 O ring Kit of 4 1 17 SPA 13 Piston Spring 1 18 SPA 320 xx K SPA 320P xx K SPA 320N xx K Stainless ste...

Page 5: ...5 Patent No WO 6006055 EP 17868788...

Page 6: ...200 600 350 SP 100 515 K Trans Tech 385 2 0 200 400 320 SP 100 522 K Trans Tech 410 2 0 200 600 350 SP 100 523 K Trans Tech 410 2 0 200 400 150 SP 100 590 K Trans Tech 218 2 0 50 150 150 SP 100 590HV...

Page 7: ...anifold 27 Type of Gun CBA2 XXX XX Spray gun complete with connecting plate CBA2U XXX XX Spray gun assembly with paint recirculation Aircap and Tip See table above A Adjusting knob B Gun head C Air ca...

Page 8: ...k the spray gun on to the connecting plate 1 The ATOM air valve controls the atomizing air pressure 2 The FAN valve reduces the spray pattern size 3 Fluid flow is adjusted with the rear ratchet knob 2...

Page 9: ...ean and free from damage Any build up of dried paint can distort the spray pattern REPLACEMENT OF PARTS Turn off air and coating supply and relieve pressure in the supply lines before any maintenance...

Page 10: ...ton ring We recommend to replace the full piston at the same time Item number SPA 60X K It s recommended to replace all the O rings 14 16 15d 15c in the gun body as soon you disassemble the Piston fro...

Page 11: ......

Page 12: ...mouth BH11 9LH England Tel No 01202 571111 Telefax No 01202 581940 Website address http www itweuropeanfinishing com ITW Finishing Systems and Products is a Division of ITW Ltd Reg Office Admiral Hous...

Reviews: