![DeVilbiss Cobra 2 Operation Manual Download Page 2](http://html1.mh-extra.com/html/devilbiss/cobra-2/cobra-2_operation-manual_2489071002.webp)
2
Operation Manual
Cobra 2 Automatic Spraygun
Important
Read and follow all instructions and Safety Precautions before using this
equipment
CHARACTERISTICS
This automatic spray gun complies to ATEX regulations 94/9/EC, protection level II 2 G X, suitable to
use in Zones 1 & 2.
This
Cobra 2
is a production spray gun suitable for use with automatic and semi-automatic machines
in conventional, HVLP or Trans-Tech applications.
Cobra 2 has a ¼ turn Quick detachable device, so to reduce maintenance & set up time (SMED).
To handle a wide range of coating materials the fluid passages are manufactured from high grade
stainless steel.
This spray gun is supplied with an indexed air cap. You can leave your air cap capable of free
rotation by removing the indexed plastic ring which is located by 2 pins on the air cap.
Pressure feed material supply can be re-circulating or direct.
The needle adjustment knob has 18 ratchet positions, allows fine and accurate fluid flow control.
SPECIFICATIONS & MATERIALS OF CONSTRUCTION
Thread Pressure
Fluid inlet & recirculation
“P”
1/8 BSP
Max 7 Bar
Air inlet (Atom+Fan)
“A” “F”
1/8 BSP
Max 7 Bar
Cylinder/trigger “C”
1/8 BSP
4 to 7 bar
Maximum temperature in use
40° C
Spray gun weight
950 g
Gun body
Aluminium hard anodized
Tip / Needle / Spray head/ Base plate
Stainless steel 303
EC Declaration of Conformity
We,
ITW Finishing UK, Ringwood Rd, Bournemouth, Dorset, BH11 9LH, UK
, as the
manufacturer of the
Spray gun model COBRA
, declare, under our sole responsibility that the
equipment to which this document relates is in conformity with the following standards or other
normative documents:
BS EN 292-1 PARTS 1 & 2: 1991, BS EN 1953: 1999;
and thereby conform to the protection
requirements of Council Directive
98/37/EEC
relating to
Machinery Safety Directive,
and;
EN 13463-1:2001,
council Directive
94/9/EC
relating to
Equipment and Protective Systems
intended for use in Potentially Explosive Atmospheres protection level II 2 G X
.
B. Holt
, General Manager
24
th
April 2007