EXPLODED PARTS VIEW
1. To replace the nozzle unscrew the hex shaped nose piece which holds the nozzle in place. Pull the nozzle out.
Be careful as it may have sharp edges.
2. Insert the new nozzle carefully - do not jam in or you will dislodge the internal tooth washer and the nozzle will
not be in the proper position. Screw the hex shaped nosepiece back on.
3. To change or replace orifices unscrew the nozzle assembly from the gun. Remove washer from end of
assembly.
4. To insert the new orifice simply drop it in, replace the washer and screw assemble onto gun.