DEVI Devireg 330 Installation And Use Instructions Manual Download Page 8

Austalian Warranty Certificate

The following Warranty is provided by DEVI Heating
Systems ABN 39 898 434 262, herein after referred to
as DEVI. It is offered in addition to any relevant statutory
Federal or State Warranty.
DEVI is a partner of the DEVI Group of Companies, who
are a Danish based specialist heating product
manufacturer.
DEVI A/S Denmark is a member of the European Group
of Supplier's, and is at all times subject to EEC general
product liability rules.

DEVI warrants deviflex® heating cables for a period of
TEN (10) YEARS from the date of purchase and all other
DEVI products for a period of TWO (2) YEARS, from the
date of purchase.

DEVI warrants its products against defects in
manufacture, material, or workmanship. Proof of
purchase must be provided. Installations must be carried
out in accordance with the instructions supplied, and by
accredited installers.

An authorized DEVI representative must be given the
opportunity to inspect and report on any defects.

The obligation of DEVI, under this warranty, is to repair or
replace any product, which, within the above stated time
periods, is found to our satisfaction to be defective, free of
charge to the customer. However, the labour cost for
removing and/or refitting any product will be at the
customer's expense.  In the case of any removable
products such as Thermostats, these are to be returned
to the place of purchase, or to DEVI Sydney, where DEVI
reserves the right to repair or replace the unit at no
charge or unreasonable delay to the customer.

Summary of Contents for Devireg 330

Page 1: ...nsor MUST be installed so that it may be REMOVED for service if required The sensor probe should be installed into a conduit with no more than one wide angle bend This should be installed from the floor to the thermostat or junction box located directly above the heated area PLEASE READ ENCLOSED INSTRUCTIONS ...

Page 2: ... an external switch or time switch 3 Thermostat must be attached to a vibration free surface 4 If the air sensor is used it must be mounted on an internal wall approx 1 5m above the floor It must not be located in the immediate vicinity of radiators doors windows or anywhere where the thermostat could be exposed to direct heat or draughts etc 5 The connection between the floor or air sensor should...

Page 3: ...that the Contactor selected is suitably sized Some Contactors can be wired to share the load between contacts however this should be confirmed with the manufacturer If a number of Contactor Circuit Breakers are mounted close together adequate ventilation space must be allowed As the deviregTM 330 is not equipped with a separate Earth Terminal the earthing screen of the heating cable must be connec...

Page 4: ...Fig 1 HEATING Fig 2 COOLING Sensor For Optional Night Set Back Only 5 6 7 8 1 2 3 4 r N A Max load 16 A 180 250V deviregTM 330 deviregTM 330 Sensor 5 6 7 8 1 2 3 4 r 180 250V N A Max load 10 A ...

Page 5: ...Fig 3 Dimensions 52mm 86 mm 61 mm 45 mm 36mm Fig 4 Loads greater than 16 Amps Cooling Heating 5 1 N N A Contactor Heating loads greater than 16 A ...

Page 6: ... P V2 57600 W at 240 V R R The calculated output of the heating cable can be determined by looking it up in your DEVI catalogue If the sensor wire terminals 7 and 8 are removed the red indicator lamp should light up and the thermostat should switch ON If not the thermostat is faulty Measuring the Sensor with an Ohmmeter should give a stable resistance compared to the ambient temperature see Techni...

Page 7: ...A 250 V Hysteresis 0 50 C Night set back 50 C Operating temperature 100 C to 500 C Moisture proof IP 20 Sensing unit NTC 15 kOhm at 250 C Sensing values 100 C 66 kOhm 00 C 42 kOhm 250 C 15 kOhm 500 C 6 kOhm LED Indicator No Light Red Green The System is OFF The Heating is ON but the preset temperature has not been reached The preset temperature has been reached and Heating is OFF ...

Page 8: ...nts its products against defects in manufacture material or workmanship Proof of purchase must be provided Installations must be carried out in accordance with the instructions supplied and by accredited installers An authorized DEVI representative must be given the opportunity to inspect and report on any defects The obligation of DEVI under this warranty is to repair or replace any product which...

Page 9: ...ncorrect installation damage by others misuse misapplication incorrect voltage lightning or incorrect design by others or where payment is in default Rectification work performed as a consequence of matters not covered by the Warranty will be at the expense of the customer DEVI will respond honestly efficiently and promptly to all queries and reasonable requests from our customers DEVI ABN 39 898 ...

Page 10: ...production The guarantee is granted on the condition that the WARRANTY CERTIFICATE on the overleaf is filled out properly in accordance to instructions and that the defect is inspected by or presented to DEVI or authorised DEVI distributor Please note that the wording of the WARRANTY CERTIFICATE must be provided in English or local language with the ISO code for your country in the upper left corn...

Page 11: ...t all times we at DEVI will respond honestly efficiently and promptly to all queries and reasonable requests from our customers The above mentioned warranty concerns product liability whereas matters in relation to legislation on sale of goods shall be referred to national law This Warranty is provided by DEVI A S Denmark Please contact your local DEVI Company for local Warranty details ...

Page 12: ...e Please Observe In order to obtain the DEVI Warranty the following must be carefully filled in See other conditions on the overleaf Electrical Installation By Installation Date Type of Thermostat Production Code DEVI DK 7100 Vejle Tlf 45 76 42 47 00 Fax 45 76 42 47 03 14 02 07 Art nr 08095103 01 01 ...