background image

E-3

III.Installation Procedure

1. Visually inspect the outside of the Paper feeder

unit, and remove locking tapes and protection
paper.

Note:

    • Locking guide tapes indicate the portions to be

unlocked; those tapes should be removed after
the completion of each unlocking procedure.

    • Being to be a lock tape even in the front door,with-

out forgetting, you remove.

2. Remove the locking tapes within the trays.

(1) Open the front door and remove locking tapes

of PF1, PF2, PF5 and Filter lever.

(2) Open the PF1 door and pull tray 4 out while

pushing the lock lever up on the left side of the
tray.

(3) Remove the locking tapes and the cushions

inside tray 4. Remove the locking guide tape
as the last step.

(4) Repeat procedures for tray 5 and close the

PF1 door and the front door.

3. Cut off the split covers on the right side of the

machine with a nipper. (2 plates)

     (Exclusive the Printer Model)

A03XIXE002CA

Locking
tapes

Locking
tapes

Locking
tapes

Locking guide tapes

Accessory
parts

Protector
sheet

A03XIXE029SA

Front door

PF1 door

A03XIXE003SA

Locking tapes

Locking guide tape

Cushion

Cushion

A03XIXE004SA

Split cover

Summary of Contents for PF-602

Page 1: ...area indicated in the photograph below Note Make sure to conduct the procedure at each person 1 Raising the front side of PF 602 to remove the 2 cushions 2 Raising the back side of PF 602 remove the 2...

Page 2: ...A03XIXC004SA 1 5 Paper path attachment A03XIXC005SA 1 6 Connector cover A03XIXC006SA 1 A03XIXC015SA 7 Top cover A A03XIXC007SA 1 8 Cushion 1 Not used on the Printer Model A03XIXC009SA 2 9 Seal P A03X...

Page 3: ...PF1 PF2 PF5 and Filter lever 2 Open the PF1 door and pull tray 4 out while pushing the lock lever up on the left side of the tray 3 Remove the locking tapes and the cushions inside tray 4 Remove the l...

Page 4: ...ws removed in step 6 8 Cut off the 4 split covers on the right side of the machine with a nipper 1 screw removed 9 Install the installation plate 1 and installation plate 2 with 2 screws apiece TP scr...

Page 5: ...acket to the machine by the 2 screws removed in step 10 15 Fix the connector plate and wire relay bracket together TP screw M3x6 2pcs 16 Tighten fully the 2 screws jointed in step 14 A03XIXE011SA Conn...

Page 6: ...2mm and more If the gap is less than 2mm adjust the gap by raising the two adjusters of the PFU right side 19 Fix the PF 602 to the machine 1 Fix the PF 602 and the installation plate on the machine u...

Page 7: ...A 22 Rotate the filter lever as indicated below and press the screw in to affix 23 Install the connector cover Truss screw black M4x6 3 pcs Align with the machine Tighten A03XIXE024SB A03XIXE030SB Cou...

Page 8: ...erial Number Setting 5 Touch Option tray according to the place where it was installed to display the Serial number entry screen 6 Enter the serial number of the PF 602 and touch OK Use Shift to switc...