Develop ineo 164 Installation Manual Download Page 3

E-3

4. Unscrew the screws shown in the illustration to

remove the imaging unit (two screws).

Note:

• Do not touch or scratch the PC drum.
• Cover the imaging unit, which has been

removed, with a protective cloth or similar mate-
rial.

5. Close the front door.
6. Remove the protective tape.
7. Push the shafts in the direction of the arrows to

remove the fixing brackets that fix the transfer
roller.

8. Close the right door.

9. Slide out the drawer and remove the developer

and cushioning material.

10. Slide the drawer back in.

A0XXIXC012MA

A0XXIXC011MA

A0XXIXC006MA

Developer

Summary of Contents for ineo 164

Page 1: ...tion proce dure This does not cause any significant change or problem with the procedure II Installation Space unit mm inch ineo 184 ineo 164 MB 503 III Pre installation Check Items 1 Install the machine at a horizontal and stable place 2 Be sure to use a power source of the voltage and frequency indicated in the product specifications Ensure that the current carrying capacity of the power outlet ...

Page 2: ... Protective Tape Packaging Materials and Imaging Unit 1 Remove pieces of protective tape and packaging materials 2 Open the right and front doors 3 Remove the cover shown in the illustration and unplug the connector one screw No Name Q ty 1 User s Guide 1 set 2 Installation Manual this manual 1 3 Developer 1 4 Power Cord 1 5 Power Cord Instruction 1 6 CD ROM 1 set After unpacking be sure to get ri...

Page 3: ... with a protective cloth or similar mate rial 5 Close the front door 6 Remove the protective tape 7 Push the shafts in the direction of the arrows to remove the fixing brackets that fix the transfer roller 8 Close the right door 9 Slide out the drawer and remove the developer and cushioning material 10 Slide the drawer back in A0XXIXC012MA A0XXIXC011MA A0XXIXC006MA Developer ...

Page 4: ...it cover three screws 4 Ready a packet of the developer and cut off one corner of the aluminum packet with scissors 5 While turning the gear in the direction of the arrow pour the developer evenly into the devel oper chamber Note Turn the magnet roller in the direction of its nor mal rotation and not the backward Be sure not to let the developer get inside the collar 6 Reinstall the developing uni...

Page 5: ...ith the guide of the machine 10 Plug the connector and then attach the cover one screw 11 Close the right and front doors 12 Plug the power cord to the machine and then to a power outlet VIII ATDC Adjustment 1 Turn on the power switch 2 Enter the service mode on the display Refer to the Service Manual to display the ser vice mode screen 3 Press or key to select FUNCTION on the display 4 Press the ...

Page 6: ...he toner can cake in the toner bottle Be sure to perform this procedure 2 Open the front door 3 Insert the toner bottle halfway with the tape side up and then slowly peel the tape off the bottle 4 Aligning the tip of the bottle tab with the mark insert the toner bottle all the way in 5 Check that the toner bottle is all the way in and then turn the toner bottle in the direction of the arrow to loc...