Panic Button - PBTZB-110
–
Technical manual
Develco Products A/S
Tangen 6
http://develcoproducts.com
DK-8200 Aarhus N
8
4
Supported Clusters
4.1
Common clusters for each end point
The ZCL “General Function Domain” clusters in this section are implemented as server clusters. Refer to ZigBee
Cluster Library Specification.
http://www.zigbee.org/Specifications.aspx
4.1.1
Basic
–
Cluster id 0x0000
Only the first set has mandatory attributes, also the optional attributes that can be relevant to a Develco device
are all in set 0x000.
4.1.1.1
Attribute
Id#
Name
Type
Range
Man/Opt
Relevance and ref.
0x0
ZCLVersion
Uint8
Type range
M
0x4
ManufacturerName
String
0-32 byte
O
4.1.1.1.1
0x5
ModelIdentifier
String
0-32 byte
O
4.1.1.1.2
0x6
DateCode
String
0-32 byte
O
0x7
PowerSource
8 bit enum
Type range
M
4.1.1.1.1
ManufacturerName
“
Develco Products A/S
”
4.1.1.1.2
ModelIdentifier
“
PBTZB-110
”
4.1.2
Identify
–
Cluster id 0x0003
4.1.2.1
Attribute
Id#
Name
Type
Range
Man/Opt
Relevance and ref.
0x0000
IdentifyTime
Uint16
Type range
M
4.1.2.2
Commands
The identify cluster has 2 commands as server.
Id#
Name
Payload
Man/Opt
Relevance and ref.
0x00
Identify
Uint16 - Identify Time (seconds)
M
0x00