![Devatec ElectroVap MC2 Series Technical Manual Download Page 7](http://html.mh-extra.com/html/devatec/electrovap-mc2-series/electrovap-mc2-series_technical-manual_2488620007.webp)
7
Pictures for illustrating purposes only
STEAM BATH MC REMOTE CONTROL
Electrical connexions
RS485 board
RS485 board
Ref: 500800/01
Steam generator main board
Ref: 500101/05
The wiring of the equipment described under must be made with a 0.75 mm2 maximum
flexible wire.
•
Clamp the RS485 board onto the DIN
rail of the steam generator.
•
Connect the RS485 grey ply to the
steam generator board
•
Wire the RS485 3 pin connector to the
Remote Control board J11 connector
with reinforced wire as follows :
485+ on 2
485– on 1
GND on 3
Remote co
ntrol
board Ref: 50
065
0/03
GND
(reinforced)
GND
(reinforced)
Reinforced wire