background image

This Quick user guide will make the installation of 

the RDS/RBDS Encoder SmartGen 4.1 

quick and 

easy. 

Applying

 these principles, you can simplify the process and save yourself extra time and effort. 

For 

more information about the Safety precautions and the Operating environment recommendations 
please refer to the

 complete

 User Manual.

1.

Install the unit on its operation place;

2.

Before  connecting  the  AC  Power,  make 

sure

  that  the  mains  supply  at  your  location

  matches

 

SmartGen 4.1

 Power Supply Factory Settings

 - 100-240 V / 50-60 Hz

3. Configure the desired operating mode - sidechain or loop-through before the device is installed in the 

signal path 

(

For more information refer to

 

Step 

&

 Step 5

); 

4. Before connecting SmartGen 4.1 to other air-chain equipment, use the SmartGen Encoders Manager 

to confirm that the encoder is properly configured; 

5. In  order  to  program  the  'static'  message  registers  and  operating  defaults,  install  the  operating 

software, before connecting the device to the computer (

Refer to 

Step 2

).

NOTE: 

We recommend testing the encoder with the controlling interface (computer, terminal, automation, 

etc.) before SmartGen 4.1 joins the air chain. This will confirm 

whether

 the encoder is properly 

initialized and two-way communication can be established. 

Connection

STEP 1

SmartGen Encoders Manager Installation

STEP 2

1.

www.devabroadcast.com/downloads;

2.

Find SmartGen 4.1 folder and double click on the installation file to launch the Wizard;

3. Accept the default recommendations and select "Next>" in the end of each step;
4. When asked to place an icon on the Desktop of your computer, make sure that the check box is 

enabled and click "Next> Finish";

5. Finally select NOT to launch the program.

Use  the  Installation  file  which  can  be  found  on  the  supplied  CD  or  downloaded  from 

USB Drivers Installation for Windows® 7

STEP 3

1.

on the Status balloon or proceed with the next step;

2.

If  an  installation  failure  occur,  a  notification  status  will 
appear. Close the status window and proceed with the next 
step;

3. To  start  the  Device  manager  go  to  Start>  Control  Panel> 

Device Manager> Other devices;

4. Right  click  on  "SmartGen"  and  select  "Update  Driver 

Software". The Update Driver Wizard will appear;

5. Click  on  "Browse  my  computer  for  driver  software"  and 

select  the  drivers  folder  (usually:  C:\Program  Files 
\SmartGen Encoders Manager\Drivers.) then click "OK" and 
"Next";

6. Windows®  7  will  advise  that  this  driver  is  'unsigned'. 

Disregard the message and click 'Install this driver software 
anyway';

7. After  the  installation  process  is  completed  a  notification 

message will be displayed.

NOTE:

 During the installation process a USB RS-232 Emulation will be made. Administrator rights might 

be needed in order for the USB drivers to be installed.

Connect the front-panel USB port to the computer. A 

"New Hardware"

 notification will appear. Click 

Summary of Contents for SmartGen 4.1

Page 1: ...dcast com SmartGen 4 1 UECP Compatible RDS RBDS Encoder with LAN USB Connectivity Quick User Guide BEFORE YOU USE THIS PRODUCT In order to be able to enjoy all the benefits of owning your new DEVA product please verify first that the latest software and firmware release were installed Visit www devabroadcast com downloads recent software and firmware downloads prior the installation for the most ...

Page 2: ...Installation STEP 2 1 www devabroadcast com downloads 2 Find SmartGen 4 1 folder and double click on the installation file to launch the Wizard 3 Accept the default recommendations and select Next in the end of each step 4 When asked to place an icon on the Desktop of your computer make sure that the check box is enabled and click Next Finish 5 Finally select NOTto launch the program Use the Insta...

Page 3: ...signal is not routed through SmartGen Mini This operating mode preserves the multiplex signal integrity and assures uninterrupted program transmission in case of encoder failure event Originally SmartGen 4 1 is configured for sidechain operation Sidechain Encoder Connection 1 Connect a BNC T adapter to the composite MPX output of the stereo generator 2 Using a suitable cable connect one side of th...

Page 4: ...will appear 2 Click on the Refresh button and using the drop down menu select the proper COM Port 3 Press OK and exit the Settings Menu 4 Different communication modes can be easily changed via the short cut placed on the bottom right of the screen Select COM communication mode and press Connect 5 Once read the Hardware configuration will be visible and ready for editing The Basic and Advanced RDS...

Page 5: ...am Type identifies the station s programming format from a list There are two lists for the European RDS system and for theAmerican RBDS specification The proper PTY can be selected from a drop down menu TATimeout An automatic timeout option has been included into SmartGen 4 1 to prevent from an extended software activated TA flag The timeout can be set choosing between 1 and 255 minutes This will...