Getting Started
For the normal operation of DB4402, you will need the following conditions:
- Standard Ethernet 10/100M connection;
- Correct assigned Network configuration and device settings;
To provide all these conditions please, follow the instructions below.
CONNECTION
1. Install the unit on its operation place;
2. Before connecting the AC Power, make sure that the fuse rating is in accordance with the
mains supply at your location. DB4402 Power Supply Factory Settings are: 100-240 VAC;
1AFuse.;
3. Connect the antenna cable to the RF antenna input connectors located on the rear panel of
the device - sections RX1 and RX2;
4. Connect the DB4402 to the TCP/IP network using two direct network cables - sections RX1
and RX2;
5. Connect the optional GSM modems via the supplied connection cable/s.
NOTE:
Please, locate and select a proper place for the GSM antenna for achieving better GSM
network coverage.
NOTE:
The GSM antenna must be far enough from the monitoring devices. The GSM modem
radiate RF signal that may cause spurious emissions that will make troubles with the accuracy of
the measurements.