LOGGER CHANNEL SETTINGS
Every Channel consists of a group of settings (explained in details below), which are used when
monitoring and alerting. Each preset has its own page where it is being configured. Measurement
windows can be set for each of the alarms, including trigger and alarm release times.
Channel
•
Name – channel alias;
•
Enable/Disable – enables/disables channel monitoring;
•
Frequency – specify the frequency to be monitored;
•
Acquisition time – specify the observation time for the current station (before switching to
the next channel).
NOTE:
When MPX Power alarm is enabled the observation time must be more than 60 seconds.
Alarm Notification Type
• E-mail – enables/disables E-mail notification;
• SMS – enables/disables SMS notification;
• SNMP – enables/disables SNMP notification;
•
GPO – enable/disable GPO action.
NOTE:
If the notification option is global disabled, notifications will not be sent, irrespective
of whether they are enabled or disabled.
Alarm
•
Range (Thresholds) – interactive slider used to adjust the Low & High thresholds on which
an alarm will be generated;
•
Trigger Time – waiting time before Active Alarm is generated;
•
Release Time – waiting time before Idle Alarm is generated;
•
RDS/RBDS Group Alarm – an alarm only for selected groups will be generated.
NOTE:
For detailed information on Alarm trigger and notifications