OUTPUTS
The general purpose outputs settings are applied through this page. The
Audio output
section
allows
Audio Vol
for the analog output to be set, and the
Digital Out
to be [Enabled] or [Disabled].
Function
,
Type
and
Pulse time
for each of the GPOs could be set individually. You can choose
between the following
Functions
:
Alarm GPO
,
RDS Lock
,
TA Flag
and
TP Flag
. Type is used
for specifying of the active level or active pulse polarity. When a GPO assigned event is triggered
the output can change the level to
Active High/Low
or to generate
High/Low Pulse
for the
specified duration.
PLEASE NOTE
that if the GPO’s function is not assigned as Alarm GPO and the selfsame is
chosen as a preferred alarm, notifications will not be indicated, nevertheless one is being generated.