Alarms
Alarm notifications
[E-mail] – global enable/disable E-mail notification;
[SNMP] – global enable/disable SNMP notification;
[GPO] – global enable/disable GPO actions.
NOTE:
If the monitoring option is disabled, notifications will not be sent, nevertheless whether
they are enabled or disabled.
RF, FM Left Audio, FM Right Audio, IP Left Audio, IP Right Audio Alarms
The settings applied to these alarms - are identical and are explained in details below.
Range
– interactive slider used to adjust the
Low & High thresholds
at which an alarm will be
generated;
Thresholds
–sets the desired
Low & High thresholds
(as explained above) but in figures.
Trigger Time
– waiting time before active alarm is generated;
Release Time
– waiting time before idle alarm is generated;