![Deutz EMS2 System Description Download Page 33](http://html1.mh-extra.com/html/deutz/ems2/ems2_system-description_2488450033.webp)
© 0702
Page 85
EMS 2
Technical data
11.6
Mechanical conditions
Free fall:
The unit must survive a free fall from a height of 1 m onto concrete or
steel in each of the three main axes without damage. Falling onto the
plug side is not taken into consideration
Vibration:
For any of the main axes, the following maximum values apply:
Amplitude:
0,35 mm
Frequency:
10 Hz to 60 Hz.
Acceleration amplitude:
50 m/s
2
Frequency:
60 Hz to 500 Hz.
Shock resistance:
According to IEC-68-2-27
Peak acceleration:
294 m/s
2
, semi-sinoidal form in each main axis
11.7
Protection class
Protection class:
IP66K according to DIN 40050.