Table 9 – Airflow data model with 1.0 HP 4-speed motor (PSC)
EXTERNAL STATIC PRESSURE WITH AIR FILTER
BLOWER SPEED
0.2” (W.C.) 0.3” (W.C.) 0.4” (W.C.) 0.5” (W.C.) 0.6” (W.C.) 0.7” (W.C.)
HIGH
2185
2115
2045
1995
1905
1820
MED-HIGH
1900
1845
1810
1760
1685
1635
MED-LOW
1475
1465
1460
1435
1380
1335
LOW
1140
1125
1110
1100
1085
1060
Table 10 – Minimum clearances from combustible materials
LOCATION
CLEARANCES RECOMMENDED ACCESS
FOR SERVICE
SIDES
FURNACE
2.54 cm (1”)
0.6 m (24”)
PLENUM AND WARM-AIR DUCT WITHIN 6ft. OF FURNACE
2.54 cm (1”)
Ø
BACK
ACCESS PANEL TO BLOWER
10.16 cm (4”)
0.6m (24”)
TOP
FURNACE OR PLENUM
5.08 cm (2”)
Ø
HORIZONTAL WARM AIR DUCT WITHIN 6FT. OF FURNACE
5.08 cm (2”)
Ø
BOTTOM
FURNACE (COMBUSTIBLE FLOOR)
0 cm (0”)
Ø
FLUE PIPE
AROUND FLUE PIPE
22.86 cm (9”)
Ø
FRONT
FURNACE
20.32 cm (8”)
0.6m (24”)