background image

ITEM

PART #

DESCRIPTION

1

B02800

Heat exchanger assembly

2

B02823

Heat exchanger support

3

B02824

Side baffle

4

B02791-01

Right side panel assembly

5

B02815

Side panel insulation

6

B02808

Heat exchanger baffles; 9x for complete kit

7

B02786-06

Front panel assembly

8

B02817

Front panel insulation

9

R02R004

High temp. control 195-30F, 7"

10

B03355

High temp. control cover

11

B02714

Gasket, breech plate

12

B02799

Breech plate, 7"

13

F07O001

Hexagonal nut 3/8-16 NC brass

14

B02111

Observation door assembly

15

F07F011

Hexagonal nut 3/8-16 NC zinc

16

L04I011

Strain relief bushing 

17

B02787-05

Blower door assembly

18

B01809

Filter rack U frame

19

B01808

Filter rack access

20

Z04F013

Paper filter 20" x 30" x 1"

21

B01406-01

Blower assembly complete

22

B01794

Blower slide 

23

B02820

Floor

24

B02830

Divider panel assembly

25

R02R002

High temp. control 140-20F, 7"

26

B02791-02

Left side panel assembly

27

B02815

Side panel insulation

28

B01684

Electric box cover

29

L01F009

Transformer 120/24 VAC

30

B01683

Electrical box complete

31

B01682

Electrical box holder plate

32

B01681

Blower slide  

33

L01I005

15 MF Capacitor

34A

R99G004

Electronic fan timer 1158-110

34B

B02797

Electrical wire kit

35

L07F003

Rocker switch SPST

36

B01024

Capacitor holder

37

B01889

Motor mount assembly

38

L06I004

3/4 hp direct drive motor, 4SD

39

B03720-05

Blower 120-10T DD

40

Z01L003

Blower wheel 120 x 10  DD

41

B02792

Back panel assembly

42

B02813

Back panel insulation

43

B02825

Rear baffle

44

B03118-01

Elect. Kit for BVSO (ext.)

45

Z06G001

Blocked vent shut-off BVSO-225

15

PARTS LIST

Model : AMP300B34-SE2PMA / OTF210G21B8

Summary of Contents for AMP300B34-SE2PMA

Page 1: ...X40093 Rev L Models AMP300B34 SE2PMA OTF210G21B INSTALLER SERVICE TECHNICIAN USE THE INFORMATION CONTAINED IN THIS MANUAL FOR THE INSTALLATION SERVICING OF THE FURNACE AND KEEP THE DOCUMENT NEAR THE...

Page 2: ...this manual can result in furnace malfunction property damage personal injury and or death WARNING Fire hazard The furnace must be installed in a level position never where it will slope toward the fr...

Page 3: ...n the water lines if possible Open faucets in appropriate areas b Have someone check the structure frequently during cold weather to make sure it is warm enough to prevent pipes from freezing Contact...

Page 4: ...ioration is discovered the chimney must be repaired or the vent must be replaced b Inspection to ascertain that the vent system is clear and free of obstructions Any blockages must be removed before i...

Page 5: ...ts and glues l Antistatic fabric softeners for clothes dryers m Acid based masonry cleaning materials 1 6 OIL TANKS AND LINES Check your local codes for the installation of the tank and accessories A...

Page 6: ...safety device must be installed between the flue outlet of the appliance and the draft regulator as indicated in the instructions It is further imperative that the BVSO be maintained annually For mor...

Page 7: ...time the burner motor ignition coil produces a spark 3 Spark ignites oil droplets 4 Cad cell senses flame and burner continues to fire Ignition transformer ceases sparking R40 F 5 After Fan Limit con...

Page 8: ...WER OFF DELAY BOARD ST9103A BLOWER ON DELAY BOARD 1158 2 2 5 Vent temperature test 1 Place a thermometer into the test hole located in the breech pipe 2 The vent temperature should be between 400 and...

Page 9: ...peration Soot will have collected in the first sections of the heat exchangers only if the burner was started after the combustion chamber was flooded with fuel oil or if the burner has been operating...

Page 10: ...remove any build up from the thermal switch surface 6 Clear and remove any build up or obstruction inside the heat transfer tube 7 Re mount lock and fasten the control box with the 2 screws removed i...

Page 11: ...BURNER MODEL 40 AHRI model AMP OTF 168 RF 189 RF 210 RF Heating capacity BTU h 139 000 155 000 171 000 Nozzle Delavan 1 00 70W 1 10 70W 1 25 70W Pump pressure PSIG 145 150 145 Combustion air adjustmen...

Page 12: ...7 6 cm 3 HORIZONTAL WARM AIR DUCT WITHIN 6 FEET OF FURNACE 2 54 cm 1 7 6 cm 3 BOTTOM FURNACE HORIZONTAL OR BELOW FLUE PIPE 23 cm 9 23 cm 9 VERTICALLY ABOVE FLUE PIPE 23 cm 9 23 cm 9 FRONT FURNACE 61...

Page 13: ...FIGURE 4 Wiring diagram AMP300B34 SE2PMA OTF210G21B 13...

Page 14: ...14 PARTS LIST Model AMP300B34 SE2PMA OTF210G21B B50046A...

Page 15: ...30 x 1 21 B01406 01 Blower assembly complete 22 B01794 Blower slide 23 B02820 Floor 24 B02830 Divider panel assembly 25 R02R002 High temp control 140 20F 7 26 B02791 02 Left side panel assembly 27 B0...