MW
Series
13
2.0
Installation
•
Lamp Installation
NOTE:
MW Series heaters are designed for use with Quartz lamp infrared heating elements only.
They
are NOT intended to be used with straight metal rod heating elements. Replace lamps with parts
from Detroit Radiant Products Company only.
Lamp Installation
Disconnect power prior to installing or replacing supplied quartz lamp(s). The elements can and should
be installed prior to mounting the heater.
1
Remove the service access panels and open lamp retainers.
2
Position heating elements in “U” slots at the ends of the reflector.
3
Close lamp retainers to secure the heating element in the slot (see Figure 2.5).
NOTE
: Avoid handling the quartz glass as much as possible. Quartz glass should be wiped off with
alcohol using a clean cloth.
4
Reinstall service access panels using sheet metal screws as removed in Step 1.
Figure 2.5
•
Lamp Installation
CAUTION
!
Element
cap
“U” Slots
End caps must be in good
electrical contact with fuse clip/