FEATURES
Cruise Switch PTO Programming Requirement and Flexibility
The digital inputs listed in Table 5-72 are required for Cruise Switch PTO.
Parameter
Group
Parameter
Options
Default
Access
13
Service Brake
Switch Con
fi
g
0 = Hardwired
1 = CCVS1
2 = CCVS2
3 = CCVS3
0 = Hardwired
VEPS, DRS
13
CC On Off Switch
Con
fi
g
0 = Hardwired
1 = CCVS1
2 = CCVS2
3 = CCVS3
0 = Hardwired
VEPS, DRS
13
CC Set Cst Res
Accel Sw Con
fi
g
0 = Hardwired
1 = CCVS1
2 = CCVS2
3 = CCVS3
0 = Hardwired
VEPS, DRS
13
Clutch Switch
Con
fi
g
0 = No Clutch Switch
1 = 1 Clutch Switch
2 = 2 Clutch Switch
3 = CCVS1
4 = CCVS2
5 = CCVS3
6 = ETC1
0 = Hardwired
VEPS, DRS
13
1 02 DI Selection
1 = Enable Park Brake Interlock
0 = Disable
2 = FUSO Auxiliary Brake
Cut Switch*
1 = Enable Park Brake
Interlock
VEPS, DRS
13
Park Brake Switch
Con
fi
g
0 = Hardwired
1 = CCVS1
2 = CCVS2
3 = CCVS3
0 = Hardwired
VEPS, DRS
13
Trans Neutral
Input Con
fi
g
0 = Hardwired
1 = Info from J1939
255 = Not Available
0 = Hardwired
VEPS, DRS
* Not supported in NAFTA
Table 5-72
Cruise Switch PTO Digital Inputs
5-138