DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
Red Stop Lamp Requirements and Guidelines
The following requirements and guidelines apply to the RSL:
□
The RSL is required.
□
A 12 volt light of less than 0.25 (DC) is required depending on the ignition source. Digital
output circuits are designed to sink no more than 0.25 (DC) current.
□
The RSL must be integrated into the instrument panel or placed in clear view of the
equipment operator.
□
The lens color must be red.
□
The words STOP ENGINE must appear on or near the RSL lamp.
Red Stop Lamp Wiring
The RSL is connected to pin 3/16 in the CPC.
See Figure 3-36 for the recommended RSL wiring.
Figure 3-36
Red Stop Lamp Wiring
All information subject to change without notice.
(Rev. 01/07)
3-109
7SA827 0701
Copyright © 2007 DETROIT DIESEL CORPORATION