Summary of Contents for EAX-300

Page 1: ......

Page 2: ...nctions STATUS INDICATOR SWITCH B OFF No indication that device is armed or disarmed ON DP SWITCH A OFF Door chime mode ON Door prop mode Default settings Will shorten battery life ARMED red LED blinks approximately every 6 seconds DISARMED green LED blinks approximately every 6 seconds STATUS INDICATOR OFF A AR B DP NOTE For Key Stop See Step 9 1 Install mortise cylinder with cylinder nut provide...

Page 3: ... mounting holes Backplate Drill 7 for 1 4 20 machine screws Drill 7 32 or 3 16 for 14 sheetmetal screws Magnet Drill 43 for 4 40 machine screws Drill 44 for 4 sheetmetal screws Backplate Drill 7 for 1 4 20 machine screws Drill 7 32 or 3 16 for 14 sheetmetal screws Mark drill backplate and magnet holes on door and frame mullion Install magnet with 2 4 40 or 4 screws Install backplate with 2 1 4 20 ...

Page 4: ...ailable for SK installations Closed contact when door is closed NOTES 1 If wire runs longer than 10 feet must use twisted pair 2 1 16 slotted jeweler screwdriver required 3 If internal contact is used DO NOT cut jumper JP1 Disconnect power cut JP1 jumper see note 3 below STEP 7 Multi door SK function wiring connection if required Recommended installation 7a 7b 7c 7d Screw wires to P1 terminal bloc...

Page 5: ...NS STEP 9 KEY STOP INSTALLATION Key stop included in hardware kit Top surface of Key Stop should NOT protrude beyond highest point on plastic cam Install key stop P N 102688 Cam orientation for Key Stop option Key and cams shown in OFF position Key and cams shown in 90 stop ON position STEP 8 INSTALL DEVICE Install device onto backplate Turn key CW to lock cover Hook at bottom then tilt cover over...

Page 6: ...oor and turn the key CCW to the ON position The red LED will flash twice indicating that the device is now armed If the door is opened the device will begin a timing countdown according to the selected amount of time 15 seconds default If the Status Indicator switch B is ON the red LED will blink every second during the countdown If the door is not closed before the door prop time runs out the ala...

Page 7: ......

Page 8: ...or external magnet Weatherized device PROBABLE CAUSE The device is setup as Door Chime PROBABLE CAUSE The device is setup as Door Prop ACTION 1 Remove battery and firmly reinstall 1 Use magnet locator to install magnet See magnet handing 2 Replace battery 3 Requires standard Yale cam 4 Microswitch needs to be replaced Remove PCB and return to Detex Repair 5 Check cylinder installation Make sure ke...