1
Model number: DI240I
Detector Inspector Smoke Alarm User Manual
Model number: DI240I Date: 2020.07.07 REV A
Read All Instructions Before Installation
Thank you for buying our smoke alarm. This manual will show you
how to install and operate it.
Please keep this manual in a safe place for future use.
AS3786:2014
DI240I Specifications:
Main Power Source
220-240 V AC/50 Hz
Secondary Power Source
DC 3V battery: Pairdeer CR17450
AC Operating Current
100mA
Interconnecting
Max. 24 alarms (wired 150m maximum) Compatible RF Module DI240WI (not included)
Operating Temperature
0 °C to 40 °C
Ambient Humidity
≤ 93%
Alarm Sensitivity
0.111-0.182dB/m
Alarm Volume
≥ 85dB(A) @ 3m
Sound Pattern
ISO8201(BI 0.5s - pause 0.5s - BI 0.5s - pause 0.5s - BI 0.5s - pause 1.5s, with the
RED LED flashing, repeat this alarm pattern)
Comply with
AS3786:2014
WARNING
•
Only an appropriately qualified electrician can install this alarm.
•
Only use this alarm for the purpose described in these instructions and ensure the installation meets with the correct
wiring rules and regulations.
•
This alarm’s wire leads may present a voltage hazard.
•
Always disconnect AC power before installing or removing.
•
Ensure the product has been correctly installed and tested for safe operation before reconnecting to electricity.
•
Do not connect the interconnection wire to the Live or Neutral terminal.
•
Non-pure sinusoidal power sources are not suitable for this smoke alarm (e.g. derived from square-wave invertors).
•
Avoid exposing this alarm to moisture.
Failure to follow these instructions may result in death or serious injury.
Product Function Description
Function
What the alarm is doing
What you need to know
Standby status
The Red LED flashes every
40 seconds.
The unit is working.
AC power indication
The Green LED continuously
illuminates.
The unit is receiving AC power.
Low battery warning
The unit chirps with Red LED
flashing every 40 seconds.
The battery is too low, replace battery as soon as possible.
Fault warning
The unit chirps between the
Red LED two times flashing.
The unit is faulty. Refer to
“Trouble Shooting”.
End-of-life warning
The unit chirps between the
Red LED flashing twice.
After 10 years the unit sends out an end-of-life warning and
will need replacing.
Test function
The Red LED flashes every
second with alarm
sounding until you release
the TEST button.
Test by pressing the TEST button for least 5 secs.
The alarm will sound if all electronic circuitry, horn and
battery are working properly.
Refer to “Trouble Shooting” if the alarm doesn’t sound.
Silence function
The Red LED flashes every
8 seconds.
This smoke alarm has a built-in Silence feature.
If cooking or other non-hazardous sources trigger the alarm,
it can be silenced for 10 mins by pressing the HUSH button
for at least 2 seconds.
After 10 mins the alarm resumes normal operation.
Fire alarm
The Red LED flashes every
second, with alarm sounds.
The alarm sounds when it detects fire.
Interconnection alarm
The alarm sounds without Red
LED flashing.
The unit will enter the interconnection alarm mode when it
receives wire interconnection alarm signals or wireless alarm
signals.
Do Not Disturb
The Red LED flashes every
40 seconds.
The unit will stop audible warnings for approximately 10 hours
from low battery or fault mode when the HUSH button is
pressed.
Pluggable module
(Optional)
Refer to the pluggable module
user manual.
Optional pluggable wireless module.
WARNING
•
If the alarm sounds, and it is not being tested, it means the unit detected smoke.
THE SOUND OF THE ALARM
REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION.
•
Before using the Silence function, identify the source of the smoke and make sure you are safe. After a 10 minute
silence, the unit will resume normal operation.
•
Do not use an open flame to test your alarm.