Detecto MedVue MV1C Setup And Operation Manual Download Page 6

8555-0550-0M Rev B 

y

 MedVue with Wi-Fi and Bluetooth 

WI-FI SETUP, CONT. 

Enable and Configure Wi-Fi Networking, Cont. 

8. With 

bLE ON/OFF

 displayed, press the 

ENTER

 key.  

9.  The display will change to show 

WIFI ON/OFF

 and the current setting. 

10. Press  the 

1

 (YES) key to select 

on

 to enable Wi-Fi and then press the 

ENTER

 key. 

11. The display will change to 

dHCP ON/OFF

 and show the current setting. Press the 

ENTER

 key if the current setting is acceptable. Otherwise, press the 

0

 (NO) or 

1

 (YES) 

key to select a new setting, and then press the 

ENTER

 key to save it. 

Allowable settings are: 

off

 or 

on

.  

NOTE:

 Select 

off

 to use a static IP address or select 

on

 to use a dynamic IP address 

assigned by a DHCP server. Consult with your network administrator for the proper 
selection. 

12. The next prompt will be 

IP1

, the first octet of the static IP address. 

a. 

If 

dHCP

 was set to 

on

, nothing needs to be entered here. Press the 

ENTER

 key until 

the prompt 

CLR WIFI CREdS

 is displayed. 

b. 

If 

dHCP

 was set to 

oFF

, using the numeric keys, enter the value for 

IP 1

, the first 

octet of the static IP address, and then press the 

ENTER

 key. For example, if the 

static IP address is “192.168.0.2”, enter 192 on the numeric keypad, and then press 
the 

ENTER

 key. 

c. 

The next three prompts will be 

IP 2

IP 3

, and 

IP 4

 for the remaining three 

octets of the IP address. Using the numeric keys, enter the value for each octet of 
the IP address, and then press the 

ENTER

 key. Repeat this for each octet. 

13. The next prompt will be 

SUbNET1

, the first octet of the network subnet mask. 

a. 

If 

dHCP

 was set to 

on

, nothing needs to be entered here. Press the 

ENTER

 key until 

the prompt 

CLR WIFI CREdS

 is displayed. 

b. 

If 

dHCP

 was set to 

oFF

, using the numeric keys, enter the value for 

SUbNET 1

, the 

first octet of the network subnet mask, and then press the 

ENTER

 key. 

c. 

 The next three prompts will be 

SUbNET 2

SUbNET 3

, and 

SUbNET 4

 for the 

remaining three octets of the subnet mask. Using the numeric keys, enter the value 
for each octet of the network subnet mask, and then press the 

ENTER

 key. Repeat 

this for each octet. 

14. The next prompt will be 

GATEWAY1

, for the first octet of the network gateway’s IP 

address. 

a. 

If 

dHCP

 was set to 

on

, nothing needs to be entered here. Press the 

ENTER

 key until 

the prompt 

CLR WIFI CREdS

 is displayed. 

b. 

If 

dHCP

 was set to 

oFF

, using the numeric keys, enter the value for 

GATEWAY 1

the first octet of the network gateway’s IP address, and then press the 

ENTER

 key. 

c. 

The next three prompts will be 

GATEWAY 2

GATEWAY 3

, and 

GATEWAY 4

 for 

the remaining three octets of the gateway’s IP address. Using the numeric keys, 
enter the value for each octet of the gateway’s IP address, and then press the 

ENTER

 key. Repeat this for each octet. 

Summary of Contents for MedVue MV1C

Page 1: ...8555 0550 0M Rev B y MV1C and MV2C with Wi Fi and Bluetooth I MV1C MedVue Medical Weight Analyzer Wi Fi and Bluetooth Setup and Operation Manual...

Page 2: ...8555 0550 0M Rev B y MedVue with Wi Fi and Bluetooth II...

Page 3: ...y and ease of application however success and safety in working with tools depend to a great extent upon the individual accuracy skill and caution For this reason the Seller is not able to guarantee t...

Page 4: ...BLE Page 9 Enable Bluetooth BLE Networking Page 9 Bluetooth Pairing Page 10 INTERFACING TO BLE Page 11 Standard Services per Bluetooth SIG Page 11 Device Information Service 0x180A Page 11 Battery Ser...

Page 5: ...or save the setting x The N G NET GROSS key is used to return to the previous menu item or setting x The ID H ID HEIGHT key is used to advance to the next menu item or setting x The 1 YES key is used...

Page 6: ...IP 2 IP 3 and IP 4 for the remaining three octets of the IP address Using the numeric keys enter the value for each octet of the IP address and then press the ENTER key Repeat this for each octet 13...

Page 7: ...press the ENTER key The credentials will be retained b To clear the credentials press the 1 YES key and then press the ENTER key The credentials will be cleared 16 The display will change to show PRI...

Page 8: ...form REDBIRD_WIFI_XX XX where XX XX is the last 4 digits of the MAC address Use a Wi Fi device such as a Smartphone tablet or laptop to connect to the MV1C If the connection fails try moving the MV1C...

Page 9: ...nd Device Name optional for the network you wish to connect to Note that the Device Name can be anything Click on the Connect button and the module should try to connect to that network This may take...

Page 10: ...play changes to show 5 Press the ID HEIGHT key until bLE WIFI is shown in the Menu area of the display 6 Press the ENTER key until the prompt CLR WIFI CREdS is displayed 7 With the display showing CLR...

Page 11: ...e MV1C is connected to a network you can access the hosted web page To view the web page proceed to the IP address of the Redbird module with webserver html added to it For example if the IP address i...

Page 12: ...x xxx weight E Zero Error clears when condition clears space None of the above conditions NOTE For E error condition xxxxxx xxx center dashes and Z O U is overridden r Range 1 2 3 etc always 1 for sin...

Page 13: ...oth BLE Networking The MV1C allows you to view and change the Bluetooth Settings without having to perform setup using the calibration switch The operational settings are entered using the keypad x Th...

Page 14: ...d back On Bluetooth Pairing To pair a Bluetooth capable device with the MV1C select the name of the MV1C from the list of available connections MV Scale XX XX XX XX XX XX Note that the X s represents...

Page 15: ...Level 0x180F 0x00 0x64 uint16 represents 0 100 percent READ Weight Scale Service 0x181D Characteristics Number Value s Attributes Weight Measurement 0x2A9D 8bit Flag uint16 weight uint16 bmi uint16 ht...

Page 16: ...les are used to transmit data to other devices software that have implemented these profiles Data is passed via BLE using GATT characteristic Weight Measurement 0x2A9D as defined by Bluetooth SIG Refe...

Page 17: ...ishes the service Characteristics Sub Number Value s Attributes Rx Cmd 0001 SMA string received by MedVue up to 20 chars WRITE Tx Cmd 0002 SMA string sent by MedVue up to 20 chars NOTIFY SMA Commands...

Page 18: ...OM error will show an E in the second space and C will show in the third space if there is a calibration error 20 SPACE W request weight 0A570D 0A 5A 31 47 20 20 30 30 30 30 30 30 2E 30 30 6C 62 0D Z1...

Page 19: ...32 3A 31 0D CAP lb 600 0 2 1 this depends on the settings of the MedVue 600 0 Capacity 2 Interval 1 Decimal 3 0A 43 4D 44 3A 48 52 49 4E 58 0D CMD HRINX 4 0A 45 4E 44 3A 0D END 5 If N is sent again yo...

Page 20: ...ENTER key to view the setting of each octet of the IP address After viewing the IP 4 setting press the ENTER key to advance to the next setting c Next 66 will be shown in the Settings area of the dis...

Page 21: ...aying for the freight both ways This warranty does not apply to peripheral equipment not manufactured by Detecto this equipment will be covered by certain manufacturer s warranty only This warranty do...

Page 22: ...onnection with the sale or use of the product Detecto will not be liable for consequential damages of any nature including but not limited to loss of profit delays or expenses whether based on tort or...

Page 23: ...8555 0550 0M Rev B y MedVue with Wi Fi and Bluetooth 19...

Page 24: ...i and Bluetooth 20 Printed in USA Cardinal Scale Manufacturing Co 102 E Daugherty Webb City MO 64870 USA Ph 417 673 4631 or 1 800 641 2008 Fax 417 673 2153 Technical Support 1 866 254 8261 E mail tech...

Reviews: