02/2014
54 / 72
6159933910
Issue no: 04
CVIR II
8.3 - pC4 format
8.3.1 - title
Char number Designation (*)
XXXX
Rdg N°
XX
sp
XX
Cy
XX
p
XX/XX/XX
Date
XX:XX:XX
time
XXXXXX
torque (Nm)
XXXXXX
Angle (dg)
XXXXXX
torque rate (Nm/dg)
XXXXXX
standby characters
XXXX
CR
(*)
depending on the language.
Example of result:
<CR>1223 01 03 01 18/04/03 09:03:45 0030.2
0120.50.5680 B <LF>
8.3.2 - Result
Char
number Designation
1
char. <CR>
4
Reading number
1
“ “
2
Spindle number
1
“ “
2
Cycle number
1
“ “
2
Phase number (= 2 blanks if cycle result)
1
“ “
8
Date in DD/MM/YY format
1
“ “
8
Time in hh:mm:ss format
2
“ “
6
Torque
2
“ “
6
Angle
2
“ “
6
Torque rate
2
“ “
6
Standby characters
2
“ “
3
Report code in 3 letters
1
<LF>
In "Print at end of cycle" mode, the reading number is
replaced by blanks.
If one of the values is missing in the unit (eg: torque
rate), it is replaced by blanks.
Example of result:
<CR>1223 02 03 00 18/04/03 09:03:45 0030.2 0120.5
0.5680 B <LF>
8.3.2.1 - Report code
(See "Report codes", page 64).
The codes emitted on letters are used for digital report
outputs or printouts.
All these codes correspond to specific displays.
The table below shows the corresponding codes
displayed.
On the contrary, if some messages on the screen do not
correspond to a letter, it means that they are not emitted.
Code emitted on 3 letters
Code displayed on
the screen
1st
Letter
2nd
Letter
3rd
Letter
“A”
“Accept”
“R”
“R”
“t”
“Tmin”
“T”
“TMAX”
“a”
“Amin”
“A”
“AMAX”
“G”
‘Grou”
“V”
“Srv”
“P”
“Prg”
“S”
“Dcy”
“i”
“Imax”
“t”
“Time”
“e”
“Ext”
“-“
“---“
Summary of Contents for CVIR II
Page 2: ......
Page 72: ...www desouttertools com More Than Productivity Copyright 2014...