How to change network parameters
Via CVIMONITOR and eDOCK
How to connect the tool to CVIMONITOR [Page 14]
Click this icon.
Click this icon to display the current parameters of the tool.
Change the parameters.
Refer to chapters
Default tool Ethernet configuration [Page 9]
.
Check that IP address, subnet mask and port number of the controller/hub are compatible.
Click this icon to write the new parameters into the tool.
Via Easy Pairing
When the pairing is done to CONNECT via RFID, WI-FI settings are directly written to the tool.
Network settings must have been done previously by using CVI CONFIG.
How to read the tool status
1
LED showing the tool status
The LED is not lit.
The synchronization with the system is required.
The tool is not allowed to run the tightening process.
The LED is blinking blue at a regular frequency.
The synchronization with the system is in progress.
The tool is not allowed to run the tightening process.
The LED is blinking blue twice at a regular frequency.
The tool is synchronized with the system but locked.
The tool is not allowed to run the tightening process.
Go to the system, press the icon "STOP" to visualize the rea-
son why the tool is locked.
The LED is steady blue.
The tool is ready to run the tightening process.
Operating Instructions
Starting the tool
Fit the tool with a suitable socket.
Select the appropriate program on the system.
Hold the tool by means of the handle and apply to the fastener to be tightened.
WARNING Risk Of Injury
As the reaction force increases in proportion to the tightening torque, there is a risk of severe bodily injury of the
operator as a result of unexpected behavior of the tool.
►
Make sure that the tool is in perfect working order and the system is programmed correctly.