Operation
EN
14 / 28
05/2020
Item
Parameter
Description
1
Pset start torque
The
Pset start torque
is the torque
value that must be reached to declare the
Pset as started.
Below this value, neither result or report
will be generated.
2
Rundown speed
Speed applied from the start to "Down-
shift torque".
3
Downshift torque
Torque value where the speed moves
from "Rundown speed" to "Downshift
speed".
4
Downshift speed
Speed applied from "Downshift torque"
to the motor stop.
How to pair a Pset to an accessory
Plug a battery pack to the tool.
This icon lights up green on the QR accessory reader.
The tool display is as follows.
Plug the accessory into the quick-release output.
See on the tool display this icon which means that the accessory has been detected.
Go to the tool display and select a Pset.
Tick
Pset enabled
, change the tightening parameters if needed and tick
QR Acc Pairing
.
Save the Pset.