To refill the pulse unit
Keep the pulse unit at normal room temperature.
A
Before the refill: Let the bubbles in the oil fade away, at least 30 min. after last run.
Check that there are no bubbles in the oil and that the pulse unit is completely full (100%)
before reducing the oil volume according to operation No. 10.
Correct oil quantity: Fill to 100%, then reduce according to table. After
the refill - check the tightening torque, and pulse frequency according
to test methods.
Approx. oil volume
in pulse-unit
Oil volume to be re-
duced from 100%
14ml
0,7 ± 0,05 ml
cs000200
8
No.: 459 663
Reduce
according to table
1 ml
2 Nm
2.5 mm
OFF
2.5 mm
Oil : 22 cSt / 40 oC (ISO VG22)
6
7
9
11
10
Fill to 100 %
1 ml
5 ml
No.: 451 213
2050505723
Part no
6
Issue no
C
Series no
2015-03
Date
55
Page