Desmi VAC-4001 Operation And Maintenance Instructions Download Page 8

 

 

DESMI PUMPING TECHNOLOGY A/S 

-8-

 

 

Tagholm 1 

 

9400 Nørresundby - Denmark 
Tel.: +45 96 32 81 11 
Fax +45 98 17 54 99 
E-mail: 

[email protected]

 

www.desmi.com

 

 

 
6.3

 

FITTING

 

NYLON

 

BUSHING 

Press nylon bushing (13) into place in the bearing bracket hub. 
 
6.4

 

FITTING

 

SHAFT

 

SEAL

 

 

Before fitting the seat, clean the recess in the rotor. When fitting the seat, remove the protective 
coating, if any, without scratching the lapped surface. Dip the outer rubber ring of the seat into 
soapy water. Now press the seat into place with the fingers and check that all parts are correctly 
imbedded. If it is necessary to use tools for assembling, protect the sliding surface of the seat to 
prevent it from being scratched or cut. Lubricate the inner diameter of the slide ring rubber bellows 
with soapy water and push it over the shaft. The use of a fitting bush as shown on the below 
assembly drawing is recommended to avoid that the rubber bellows is cut. Push the slide ring over 
the shaft with the hand. If the rubber bellows is tight, use a fitting tool and take care that the slide 
ring is not damaged. 
 

If the carbon ring is not fixed, it is important to check that it is fitted correctly, i.e. the 
chamfered/lapped side is to face the seat. The carbon ring can be held by a little grease. 
When using oil on the shaft, the bellows will settle and seat in about 15 minutes, and until then 
tightness should not be expected. 
 
6.5

 

FITTING

 

ROTOR 

Fit locating pin (18) in the rotor hub. Place rear plate (14) in the recess of the nylon bushing and 
lead the rotor over the shaft and against the shoulder of the shaft. Mount the rotor housing (17) on 
the rear plate (14) by means of the Allen screws (15). 
 
6.6

 

FITTING

 

IMPELLER 

Fit the sunk key (9) in the shaft and lead the impeller towards the shoulder of the shaft. Take care 
that the pin is placed in the hole of the impeller hub. Secure the impeller with a washer (37) and a 
nut (21). 
 
6.7

 

FITTING

 

BEARING

 

BRACKET

  

 

Place the O-ring (12) that seals between pump casing and bearing bracket on the bearing bracket  
where it can be held with a little silicone grease. Lead bearing bracket into place and fasten with 
nuts (1). Mount drain plug (7) and fill bearing bracket with oil (SAE 15W40) until half the shaft is 
covered. 
 
6.8

 

SHAFT 

When the pump has been assembled, check that the shaft rotates freely. 

 
 
7.

 

FROST

 

PROTECTION 

 
Pumps which are not in operation during frost periods are to be drained to avoid frost damage. 
Remove the drain bolt (32) at the bottom to empty the pump. Alternatively, it is possible to use anti-
freeze liquids in normal constructions. 
 

Fitting bush

Summary of Contents for VAC-4001

Page 1: ...C 4001 DESMI PUMPING TECHNOLOGY A S Tagholm 1 DK 9400 N rresundby Denmark Tel 45 96 32 81 11 Fax 45 98 17 54 99 E mail desmi desmi com Internet www desmi com Manual T1449 Language English Revision C 0...

Page 2: ...TLING SHAFT WITH BEARINGS 7 5 6 INSPECTION 7 6 ASSEMBLING 7 6 1 FITTING SEALING RING IN PUMP CASING 7 6 2 FITTING SHAFT WITH BEARINGS 7 6 3 FITTING NYLON BUSHING 8 6 4 FITTING SHAFT SEAL 8 6 5 FITTING...

Page 3: ...ns is 3600 RPM The pump is particularly suitable for bilge pumping and for use in piping systems where large amounts of air have to be evacuated The VAC 4001 pump is a quality product manufactured in...

Page 4: ...is to be evaluated on the basis of the materials used in the pump In case of doubt contact the supplier Pumps in material combinations A are primarily used for fresh water Pumps in material combinatio...

Page 5: ...er than the impeller gap of the pump in question In order to secure priming of the pump the pressure pipe is to be arranged so that water locks in the pipe are avoided If the pump is to be driven by a...

Page 6: ...workmen according to the rules and regulations in force 4 TRANSPORT STORAGE The weights of the pumps are stated in the following table and the pumps are to be lifted as shown below Pump Weight kg VAC...

Page 7: ...14 and nylon bushing 13 5 3 DISMANTLING SHAFT SEAL Pull the shaft seal off the shaft 5 4 DISMANTLING SEAT Pull the shaft seal seat carefully out of the recess of the rotor hub 5 5 DISMANTLING SHAFT WI...

Page 8: ...lapped side is to face the seat The carbon ring can be held by a little grease When using oil on the shaft the bellows will settle and seat in about 15 minutes and until then tightness should not be e...

Page 9: ...pump casing is filled with liquid Start the pump for a moment to check direction of rotation If the direction is correct i e in the direction of the arrow the pump may be started 10 SYSTEM BALANCING I...

Page 10: ...oning Contact DESMI Ventilate the system The pump has no or too low capacity 1 Wrong direction of rotation 2 Piping system choked 3 The pump is choked 4 Suction line leaks Pump takes air 5 Suction lif...

Page 11: ...orking hours when direct coupled to electric motor whereas the nominal life with overhanging V belt drive is about 10 000 working hours The bearings are oil lubricated and they only require that the o...

Page 12: ...s Common safety requirements EN12162 2001 A1 2009 Liquid pumps Safety requirements Procedure for hydrostatic testing EN 60204 1 2006 A1 2009 Safety of machinery Electrical equipment of machines item 4...

Page 13: ...DESMI PUMPING TECHNOLOGY A S 13 Tagholm 1 9400 N rresundby Denmark Tel 45 96 32 81 11 Fax 45 98 17 54 99 E mail desmi desmi com www desmi com 15 ASSEMBLY DRAWING...

Page 14: ...r housing 1 190531 15 Allen screw M5x30 4 710940 16 Rotor 1 190532 17 Rotor housing 1 190533 18 Locating pin 4x18 1 706284 19 Impeller 1 590730 20 Key 5x5x20 1 700012 21 Impeller nut M18x1 5 1 710943...

Page 15: ...DESMI PUMPING TECHNOLOGY A S 15 Tagholm 1 9400 N rresundby Denmark Tel 45 96 32 81 11 Fax 45 98 17 54 99 E mail desmi desmi com www desmi com 17 DIMENSIONAL SKETCH...

Reviews: