This Manual is applicable to Soft LED8
Revised on August 2018
ILT ITALY srl
Via Cancelliera, 10/a
00041 Albano Laziale (Rome) Italy
tel. +39 06-902901 fax +39 06-90231051
www.desisti.it
D.
In case of pole operated use, fit only a P.O. stirrup from De Sisti Lighting.
E.
A suitable secondary safety suspension device (safety cable, chain or equivalent) must be fitted between the suspension point and the eyelet
at the front of the body
F.
WARNING : DO NOT MOUNT THE LUMINAIRE ON A NORMALLY FLAMMABLE SURFACE
5.
INSTALLATION INSTRUCTIONS
The following procedure should be adopted:
Before connecting the luminaire to the electrical mains ensure that:
A.
Earth line is present on the power socket.
B.
The mains voltage is within the rated range of the luminaire (see technical data on the rating label)
C.
The front safety Shield is present and in good condition.
It consists of a Remote Phosphors Panel 305 x 107 mm.
WARNINGS :
•
Do not operate the product if the ambient temperature exceeds 40° C
•
Provide a minimum clearance of 0,1m (4 in.) around fans and air vents.
•
SHIELDS, LENSES SAFETY OR DICHROIC GLASSES SHALL BE CHANGED IF THEY HAVE BECOME VISIBLY DAMAGED TO SUCH
AN EXTENT THAT THEIR EFFECTIVENESS IS IMPAIRED, FOR EXAMPLE BY CRACKS OR DEEP SCRATCHES.
•
THE LUMINAIRE SHALL ONLY BE USED COMPLETE WITH ITS PROTECTIVE SHIELD
D.
Applying power:
Never connect to dimmer power. Install a power plug on the power cable using the following pin assigment:
1 : Neutral 2 : Live Green/Yellow : Ground - This fixture must be connected to ground.
Make sure the local power voltage is within the range specified. If so; connect the power cable and turn the power on.
E.
Stand Alone operation:
Using the navigation buttons and display readout ( refer to the “Local Menu” chapter )
navigate to Manual and set the desired intensity (for additional operations see “Local Menu” chapter)
F.
DMX operation:
Connect a DMX cable
Navigate to Address mode (Addr) and set the desired address, (refer to the “Local Menu” chapter).
Connect to DMX controller (refer to the “Channel Setting” in the “Local Menu” chapter) and Use it.
6.
LOCAL MENU
The SOFT LED8 has a GRAPHIC DISPLAY backlit, with two local knobs, each one having a push/click function in addition to the
rotation:
KNOB 1
It is as a DEFAULT the FAST ACTION Knob, By pushing it, it provides a
FAST ACTION on the KNOB 2 which is normally the DIMMING
Display
It is a Graphic, backlit LCD Display. It contains all the relevant information for the product setup
and performances, such as DMX Address, DMX Level, LED Temperature and local dimming.
When the local
knobs are not used for more than 5 seconds the display back illumination will go OFF and the display itself
will go in STAND BY Mode. It will go ON again anytime a KNOB is activated.
KNOB 2
It is as a DEFAULT the DIMMING Variation Knob, By rotating it clockwise the Dimming of the
Light Changes from 0up to Full Light Output. If such a knob is pushed, it has the selection or enter function
to, for instance, enter into a Menu