background image

 

 

 

This Manual is applicable to Soft LED8 

 

Revised on August 2018

 

 

 

ILT ITALY srl 

Via Cancelliera, 10/a  
00041 Albano Laziale (Rome) Italy 
tel. +39 06-902901 fax +39 06-90231051 
www.desisti.it 

 
 

D.

 

In case of pole operated use, fit only a P.O. stirrup from De Sisti Lighting. 

E.

 

A suitable secondary safety suspension device (safety cable, chain or equivalent) must be fitted between the suspension point and the eyelet 
at the front of the body 

F.

 

 

WARNING : DO NOT  MOUNT THE LUMINAIRE ON A NORMALLY FLAMMABLE SURFACE 

 

5.

 

INSTALLATION INSTRUCTIONS 

 

The following procedure should be adopted: 
 
Before connecting the luminaire to the electrical mains ensure that: 

A.

 

Earth line is present on the power socket. 

B.

 

The mains voltage is within the rated range of the luminaire (see technical data on the rating label) 

C.

 

The front safety Shield is present and in good condition. 
It consists of a Remote Phosphors Panel 305 x 107 mm. 

 
             

WARNINGS :  

 

Do not operate the product if the ambient temperature exceeds 40° C 

 

Provide a minimum clearance of 0,1m (4 in.) around fans and air vents. 

 

SHIELDS, LENSES SAFETY OR DICHROIC GLASSES SHALL BE CHANGED IF THEY HAVE BECOME VISIBLY DAMAGED TO SUCH 
AN EXTENT THAT THEIR EFFECTIVENESS IS IMPAIRED, FOR EXAMPLE BY CRACKS OR DEEP SCRATCHES.  

 

THE LUMINAIRE  SHALL ONLY BE USED  COMPLETE  WITH ITS PROTECTIVE SHIELD 

 

D.

 

Applying power: 

Never connect to dimmer power. Install a power plug on the power cable using the following pin assigment: 

1 : Neutral   2 : Live   Green/Yellow : Ground - This fixture must be connected to ground. 

Make sure the local power voltage is within the range specified. If so; connect the power cable and turn the power on. 
 

E.

 

Stand Alone operation: 

Using the navigation buttons and display readout ( refer to the “Local Menu” chapter ) 
navigate to Manual and set the desired intensity (for additional operations see “Local Menu” chapter) 
 

F.

 

DMX operation: 

Connect a DMX cable 
Navigate to Address mode (Addr) and set the desired address, (refer to the “Local Menu” chapter). 
Connect to DMX controller (refer to the “Channel Setting” in the “Local Menu” chapter) and Use it. 

 

6.

 

LOCAL MENU 

 

The SOFT LED8  has a GRAPHIC DISPLAY backlit, with two local knobs, each one having a push/click function in addition to the 
rotation: 
                                                                                      
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

KNOB 1

   

It is as a DEFAULT the FAST ACTION Knob, By pushing it, it provides a 
FAST ACTION on the KNOB 2 which is normally the DIMMING

 

Display

 

It is a Graphic, backlit LCD Display. It contains all the relevant information for the product setup 

and performances, such as DMX Address, DMX Level, LED Temperature and local dimming. 

When the local 

knobs are not used for more than 5 seconds the display back illumination will go OFF and the display itself 
will go in STAND BY Mode. It will go ON again anytime a KNOB is activated. 

 

KNOB 2

 

It is as a DEFAULT the DIMMING Variation Knob, By rotating it clockwise the Dimming of the  

Light Changes from 0up to Full Light Output. If such a knob is pushed, it has the selection or enter function 
to, for instance, enter into a Menu

 

Summary of Contents for SOFT LED 8

Page 1: ...an depend upon the quality of this product The SOFT LED 8 is a innovative Remote Phosphors 360W LED SOFTLIGHT with a COLOR RENDERING INDEX CRI higher than 95 for the Tungsten CCT and Higher than 91 fo...

Page 2: ...anual is applicable to Soft LED8 Revised on August 2018 ILT ITALY srl Via Cancelliera 10 a 00041 Albano Laziale Rome Italy tel 39 06 902901 fax 39 06 90231051 www desisti it 2 YOKE AND ACCESSORIES ASS...

Page 3: ...Green or green yellow Neutral Blue White Live Brown Black In case the colors of the cores do not correspond to the colors of the connection points on your plug please proceed as follows the green or g...

Page 4: ...he power cable using the following pin assigment 1 Neutral 2 Live Green Yellow Ground This fixture must be connected to ground Make sure the local power voltage is within the range specified If so con...

Page 5: ...icture it is required to reach the DMX addr Menu select the preferred base DMX Address and Select it 1st menu displayed 2nd menu displayed Explanation of each menu function CHANNEL SETTING RESOLUTION...

Page 6: ...OCAL DIMMING and CCT SETTINGS and maintain it when the POWER is turned off and than on again This allows for the LIGHT to be TUNED and FOCUSED locally and its dimming plus CCT level can be blocked so...

Page 7: ...osphors Panel with a soft damp cloth 4 Check the condition of the safety shield see chapter Installation Instructions before every use 5 Check Power supply cable and DMX control cable proper condition...