6.
CHARACTERISTICS AND PERFORMANCE DATA
DESCRIPTION
VALUE
- Amperage
Europe – 230V
2,9 A (650 W)
America 120 V
5.5 A (650 W)
- Power Supply
Europe
230 V – 0-60 Hz
America
120 V / 0-60 Hz
- Switch on line
M.O. & P.O.
Toggle: 16A/125V 8A/250V
Lamp Holder
GY 9,5
Power Cable
Europe
3 x 1,5 mm
2
– 150°C
(0,5 m silicon 180°C + 3 m H07RN-F 90°C)
3 x 16 Awg
(0,5 m high T 200°C
+ 3m SO 90°C + Plug)
Protection Class
Class 1 – ground connection required
Protection Type
IP 22
Max. housing surface temeprature 220°C
Weight of fixture
M.O.
4,7 kg
P.O
Kg..
Weight of barndoor
4 leaf
kg.
8 leaf
kg
Size of barndoor ring
Seat diameter
mm
Ring diameter
mm (7’’
½
)
Size of scrims & color frame
Seat diameter
mm
Accessory diameter
mm (7’’
¼
)
Lens diameter
120 mm
USABLE LAMPS
base-watt-filament
230 V
120 V
ANSI
LIF
ANSI
LIF
GY 9,5 – 300 W – M Sh
FSL
CP 81
FKW
CP 81
GY 9,5 – 500 W - MP
FRH
CP 82
FRG
CP 82
GY 9,5 – 650 W - MP
FRL
CP 89
FRK
CP 89
7.
PERIODIC INSPECTION
A.
The condition of the internal wiring insulation and of the input cable shall be inspected and tested every
500 working hours and at least once a year. This frequency may need to be increased if rough or unknown
(eg. Rental) treatment is incurred. Replace only with original De Sisti spare parts. Non-original cables may
not withstand the thermal and mechanical conditions of use
B.
The lamp condition must be checked every 100 working hours. For lamp replacement follow the procedure
of point 5 and the instruction of the lamp manufacturer.
C.
Check the condition of the safety shield (see chapter 4-D – Installation Instructions) before every use.
8.
SAFETY STANDARDS
Europe: The product conforms the Applicable European Directives &
Standards
America: the product
conforms NEC & UL stds.
-
Low voltage directive: 73/23/EEC (as amended by 93/68/EEC)
-
EMC Directive: 89/336/EEC (as amended by 92/31/EEC & by
93/68/EEC)
-
European Standards: EN 60598-2-17, EN 60598-1, EN 61547
UL Standard: 1573
Approved by UL: file
E116219